Three partial factors in EN 1993-1-1, and they are not…
By Daniel Weber,
Three partial factors in EN 1993-1-1, and they are not interchangeable.
γM0 = 1.00 for cross-section resistance, γM1 = 1.00 for member buckling, γM2 = 1.25 for the net section in tension and for bolts and welds.
The 1.25 is there because those failures are brittle and scatter more. National Annexes may change all three, so check the NA before trusting a default. #eurocode3 #steeldesign
Replies
Lukas Novák:
The one that surprises people is that γM2 also applies to the net section in tension while the gross section stays on γM0. Two factors in the same member check.
Kenji Watanabe (reply):
And the net section has its own 0.9 factor on top, so Nu,Rd = 0.9 Anet fu / γM2. It is easy to apply one and forget the other.
Dr. Sarah Chen:
Several National Annexes set γM1 = 1.10 rather than 1.00. Worth reading before reusing a spreadsheet from another country.