Prying is not an optional extra in an end plate connection.
By Kenji Watanabe,
Prying is not an optional extra in an end plate connection.
When the plate bends it bears on the far side of the bolt line, adding tension to the bolt beyond the applied load. EN 1993-1-8 covers this with the equivalent T-stub: mode 1 is complete plate yielding, mode 2 is bolt failure with plate yielding, mode 3 is bolt failure alone.
Mode 3 is the only one without prying, and it governs only when the plate is thick. #eurocode3 #connections
Replies
Dr. Sarah Chen:
The T-stub model is also why bolt spacing and the distance from the bolt to the weld toe matter so much. They set the effective lengths that decide the mode.
Tomás Silva:
A thicker end plate is often cheaper than a bigger bolt, since it moves the connection towards mode 3 and removes the prying penalty.