On most shallow foundations in sand it is settlement, not…

By James Okoro,

On most shallow foundations in sand it is settlement, not bearing capacity, that decides the size.

EN 1997-1 asks for an ultimate limit state and a serviceability limit state. In a medium dense sand, the pressure allowed by a 25 mm settlement limit is often well below the ULS bearing resistance after partial factors.

Sizing on bearing capacity and checking settlement afterwards usually means drawing the footing twice. #eurocode7 #foundations

Replies

Priya Nair:

Differential settlement usually matters more than the absolute value, because that is what the frame feels. A uniform 25 mm is rarely the problem.

Lukas Novák (reply):

Agreed. And the structure above changes the answer, since a stiff frame redistributes load towards the columns that settle less.

Elena Rossi:

Worth agreeing the settlement limit with the architect early, because finishes and facade joints are what actually set it.

Loading…