Beam shear to EC2 lets you choose the strut angle θ between…

By CivilAxis,

Beam shear to EC2 lets you choose the strut angle θ between 21.8° and 45° (cot θ from 1 to 2.5).

A flatter strut needs fewer links but pulls more force into the longitudinal steel. VRd,max sets the upper bound, so a beam with a high shear force often ends up near 45°. #eurocode2 #shear

Replies

Priya Nair:

And with a flatter strut the additional tensile force ΔFtd = 0.5 VEd (cot θ - cot α) grows, so the curtailment points move too.

Hannah Moore:

Is cot θ = 2.5 the usual starting point then?

CivilAxis (reply):

Often, yes. Start at 2.5 and reduce it only if VEd exceeds VRd,max at that angle.