High-Strength Bolt Strengths (F3125 A325 / A490) - AISC 360

CivilAxisCivilAxis
/
CODE & STANDARDS
DESIGN STANDARDS LIBRARY
☕ Support🌐 Community
RCSC Parts
Tables

High-Strength Bolt Strengths (F3125)

Nominal tensile Fnt and shear Fnv (ksi) for A325 & A490 - AISC 360 Table J3.2

GradeGroupFnt (ksi)Fnv - N (ksi)Fnv - X (ksi)
F3125 Gr. A325A905468
F3125 Gr. A490B1136884
Fnv depends on whether bolt threads are excluded (X) or included (N) in the shear plane. Fnt = 0.75 × bolt tensile strength.