CivilAxisCivilAxis
☕ Support🌐 Community

W 12X45 vs H-300x150x11x18

W 12X45 is an W section from the American AISC Shapes Database; H-300x150x11x18 is the closest equivalent in the European (Continental) range. They are close to interchangeable in bending: 1052 cm³ against 1070 cm³ of plastic modulus, a difference of 1.7%. W 12X45 is the lighter of the two at 67 kg/m against 69 kg/m, a saving of 2.9% on steel weight. H-300x150x11x18 is deeper, 318 mm against 307.3 mm, which matters where the floor zone is tight.

Section properties side by side. Bold marks the more favourable value where one is.
PropertyW 12X45
W
H-300x150x11x18
MB & MC
Difference
Mass67 kg/m69 kg/m-2.9%
Depth307.3 mm318 mm-3.4%
Width204.5 mm154 mm+32.8%
Web thickness8.5 mm11 mm-22.7%
Flange thickness14.6 mm18 mm-18.9%
Area84.5 cm²87.9 cm²-3.9%
Second moment, major (Iy)14,485 cm⁴14,820 cm⁴-2.3%
Plastic modulus, major (Wpl,y)1,052 cm³1,070 cm³-1.7%
Elastic modulus, major (Wel,y)945.53 cm³932 cm³+1.5%
Second moment, minor (Iz)2,081 cm⁴1,100 cm⁴+89.2%
Plastic modulus, minor (Wpl,z)311.35 cm³223 cm³+39.6%
Radius of gyration, minor (iz)4.95 cm3.54 cm+39.8%
Torsion constant (It)52.45 cm⁴79 cm⁴-33.6%

W 12X45 to AISC Shapes Database v16.0; H-300x150x11x18 to Continental Steel. Difference is expressed relative to H-300x150x11x18.

How to choose between them

On stiffness, H-300x150x11x18 has the larger second moment of area: 14,820 cm⁴ against 14,485 cm⁴, a difference of 2.3%. This matters more often than the strength comparison, because on normal floor spans deflection rather than bending capacity sets the beam size - so if the two are close on modulus but apart on inertia, the stiffer one is usually the better answer even when it is not the stronger one.

Measured as bending capacity per kilogram, the two are equally efficient (15.7 against 15.5 cm³ per kg/m), so on a pure steel-tonnage basis there is nothing to choose between them. The decision comes down to availability, connection detailing and what the rest of the frame uses.

The two diverge much more about the minor axis: W 12X45 has 311.35 cm³ of minor-axis plastic modulus against 223 cm³, 39.6% more. If the member sees any minor-axis bending, or if it is unrestrained over a long length and lateral-torsional buckling governs, that gap decides the comparison even though the major-axis numbers looked equivalent.

These come from different catalogues, so treat the swap as a design change rather than a like-for-like substitution. W sections are specified to AISC Shapes Database v16.0 and MB & MC to Continental Steel; the steel grades, tolerances and available lengths differ, connection details and bolt gauges are set out differently, and the two are rarely both stocked in the same market. Check availability before changing a section on a drawing to save 2.9% weight.

In short, H-300x150x11x18 is the stronger section and W 12X45 is the lighter one; where those are the same section, it is the clear choice, and where they are not, decide on whether your design is governed by capacity or by tonnage.

Common questions

They are effectively equal in bending. W 12X45 has a plastic modulus of 1052 cm³ and H-300x150x11x18 has 1070 cm³, a difference of only 1.7% - within the margin that section choice normally turns on. Compare stiffness and availability instead.

W 12X45 at 67 kg/m, against 69 kg/m for the other - a saving of 2.9%. Over a repeated floor beam that is a real cost difference, but check it against the deflection case before taking it.

Structurally it is the closest equivalent we hold: H-300x150x11x18 gives 1070 cm³ of plastic modulus and 14,820 cm⁴ of inertia against 1052 cm³ and 14,485 cm⁴. But they are from different catalogues (AISC Shapes Database v16.0 and Continental Steel), so this is a design change, not a drop-in swap: re-check deflection, connection detailing and local availability.

H-300x150x11x18, with a second moment of area of 14,820 cm⁴ against 14,485 cm⁴ (2.3% more). Deflection under a uniform load goes as 5wL⁴/384EI, so it is inversely proportional to I - on a span where the deflection limit governs rather than strength, this is the number that decides the section.

Related comparisons

W 12X45 vs HE 300 AAW 12X45 vs S 12X50
Rate this
No ratings yet
Sign in to join the discussion.
Loading…