CivilAxisCivilAxis
☕ Support🌐 Community

WT 5X11 vs Tee 102×127×14

WT 5X11 is an WT section from the American AISC Shapes Database; Tee 102×127×14 is the closest equivalent in the UK Blue Book (SCI P363). They are close to interchangeable in bending: 49.489 cm³ against 50.4 cm³ of plastic modulus, a difference of 1.8%. Tee 102×127×14 is the lighter of the two at 14.1 kg/m against 16.4 kg/m, a saving of 16.3% on steel weight. Both are about 130 mm deep, so either fits the same construction zone.

Section properties side by side. Bold marks the more favourable value where one is.
PropertyWT 5X11
WT
Tee 102×127×14
Tees (from UB)
Difference
Mass16.4 kg/m14.1 kg/m+16.3%
Depth129.3 mm130.1 mm-0.6%
Width146 mm102.2 mm+42.9%
Web thickness6.1 mm6.3 mm-3.2%
Flange thickness9.1 mm10 mm-9.0%
Area20.9 cm²18 cm²+16.1%
Second moment, major (Iy)286.4 cm⁴277 cm⁴+3.4%
Plastic modulus, major (Wpl,y)49.489 cm³50.4 cm³-1.8%
Elastic modulus, major (Wel,y)28.186 cm³28.3 cm³-0.4%
Second moment, minor (Iz)237.7 cm⁴89.3 cm⁴+166.2%
Plastic modulus, minor (Wpl,z)49.981 cm³27.4 cm³+82.4%
Radius of gyration, minor (iz)3.38 cm2.22 cm+52.3%
Torsion constant (It)4.95 cm⁴4.77 cm⁴+3.8%

WT 5X11 to AISC Shapes Database v16.0; Tee 102×127×14 to BS EN 10365:2017. Difference is expressed relative to Tee 102×127×14.

How to choose between them

On stiffness, WT 5X11 has the larger second moment of area: 286.4 cm⁴ against 277 cm⁴, a difference of 3.4%. This matters more often than the strength comparison, because on normal floor spans deflection rather than bending capacity sets the beam size - so if the two are close on modulus but apart on inertia, the stiffer one is usually the better answer even when it is not the stronger one.

Measured as bending capacity per kilogram of steel, Tee 102×127×14 is the more efficient section: 3.6 against 3.0 cm³ per kg/m, 15.6% better. Over a floor of repeated beams that difference is real tonnage, though it is often outweighed by whichever section the fabricator can actually source.

The two diverge much more about the minor axis: WT 5X11 has 49.981 cm³ of minor-axis plastic modulus against 27.4 cm³, 82.4% more. If the member sees any minor-axis bending, or if it is unrestrained over a long length and lateral-torsional buckling governs, that gap decides the comparison even though the major-axis numbers looked equivalent.

These come from different catalogues, so treat the swap as a design change rather than a like-for-like substitution. WT sections are specified to AISC Shapes Database v16.0 and Tees (from UB) to BS EN 10365:2017; the steel grades, tolerances and available lengths differ, connection details and bolt gauges are set out differently, and the two are rarely both stocked in the same market. Check availability before changing a section on a drawing to save 16.3% weight.

In short, Tee 102×127×14 is the stronger section and Tee 102×127×14 is the lighter one; where those are the same section, it is the clear choice, and where they are not, decide on whether your design is governed by capacity or by tonnage.

Common questions

They are effectively equal in bending. WT 5X11 has a plastic modulus of 49.489 cm³ and Tee 102×127×14 has 50.4 cm³, a difference of only 1.8% - within the margin that section choice normally turns on. Compare stiffness and availability instead.

Tee 102×127×14 at 14.1 kg/m, against 16.4 kg/m for the other - a saving of 16.3%. Over a repeated floor beam that is a real cost difference, but check it against the deflection case before taking it.

Structurally it is the closest equivalent we hold: Tee 102×127×14 gives 50.4 cm³ of plastic modulus and 277 cm⁴ of inertia against 49.489 cm³ and 286.4 cm⁴. But they are from different catalogues (AISC Shapes Database v16.0 and BS EN 10365:2017), so this is a design change, not a drop-in swap: re-check deflection, connection detailing and local availability.

WT 5X11, with a second moment of area of 286.4 cm⁴ against 277 cm⁴ (3.4% more). Deflection under a uniform load goes as 5wL⁴/384EI, so it is inversely proportional to I - on a span where the deflection limit governs rather than strength, this is the number that decides the section.

Related comparisons

Tee 102×127×14 vs WT 5X9.5
Rate this