CivilAxisCivilAxis
☕ Support🌐 Community

RHS 100×60×7.1 vs RHS 100×75×6

RHS 100×60×7.1 is an RHS Hot-finished section from the UK Blue Book (SCI P363); RHS 100×75×6 is the closest equivalent in the European (Continental) range. RHS 100×60×7.1 carries more bending: 62.9 cm³ of plastic modulus against 61 cm³, 3.1% more. RHS 100×75×6 is the lighter of the two at 15.1 kg/m against 15.8 kg/m, a saving of 4.6% on steel weight. Both are about 100 mm deep, so either fits the same construction zone.

Section properties side by side. Bold marks the more favourable value where one is.
PropertyRHS 100×60×7.1
RHS Hot-finished
RHS 100×75×6
RHS Cold-formed
Difference
Mass15.8 kg/m15.1 kg/m+4.6%
Depth100 mm100 mmsame
Width60 mm75 mm-20.0%
Web thickness0 mm0 mmsame
Flange thickness0 mm0 mmsame
Area20.2 cm²18.6 cm²+8.6%
Second moment, major (Iy)244 cm⁴245 cm⁴-0.4%
Plastic modulus, major (Wpl,y)62.9 cm³61 cm³+3.1%
Elastic modulus, major (Wel,y)48.8 cm³49 cm³-0.4%
Second moment, minor (Iz)106 cm⁴156 cm⁴-32.1%
Plastic modulus, minor (Wpl,z)43.2 cm³49.9 cm³-13.4%
Radius of gyration, minor (iz)2.29 cm2.89 cm-20.8%
Torsion constant (It)245 cm⁴320 cm⁴-23.4%

RHS 100×60×7.1 to BS EN 10210-2:2006; RHS 100×75×6 to EN 10219 · Continental Steel. Difference is expressed relative to RHS 100×75×6.

How to choose between them

On stiffness, RHS 100×75×6 has the larger second moment of area: 245 cm⁴ against 244 cm⁴, a difference of 0.4%. This matters more often than the strength comparison, because on normal floor spans deflection rather than bending capacity sets the beam size - so if the two are close on modulus but apart on inertia, the stiffer one is usually the better answer even when it is not the stronger one.

Measured as bending capacity per kilogram, the two are equally efficient (4.0 against 4.0 cm³ per kg/m), so on a pure steel-tonnage basis there is nothing to choose between them. The decision comes down to availability, connection detailing and what the rest of the frame uses.

The two diverge much more about the minor axis: RHS 100×75×6 has 49.9 cm³ of minor-axis plastic modulus against 43.2 cm³, 13.4% more. If the member sees any minor-axis bending, or if it is unrestrained over a long length and lateral-torsional buckling governs, that gap decides the comparison even though the major-axis numbers looked equivalent.

These come from different catalogues, so treat the swap as a design change rather than a like-for-like substitution. RHS Hot-finished sections are specified to BS EN 10210-2:2006 and RHS Cold-formed to EN 10219 · Continental Steel; the steel grades, tolerances and available lengths differ, connection details and bolt gauges are set out differently, and the two are rarely both stocked in the same market. Check availability before changing a section on a drawing to save 4.6% weight.

In short, RHS 100×60×7.1 is the stronger section and RHS 100×75×6 is the lighter one; where those are the same section, it is the clear choice, and where they are not, decide on whether your design is governed by capacity or by tonnage.

Common questions

RHS 100×60×7.1 is the stronger of the two in bending, with a plastic modulus of 62.9 cm³ against 61 cm³ - 3.1% more. At the same steel grade that translates directly into moment capacity, since M_pl,Rd = W_pl x f_y / gamma_M0.

RHS 100×75×6 at 15.1 kg/m, against 15.8 kg/m for the other - a saving of 4.6%. Over a repeated floor beam that is a real cost difference, but check it against the deflection case before taking it.

Structurally it is the closest equivalent we hold: RHS 100×75×6 gives 61 cm³ of plastic modulus and 245 cm⁴ of inertia against 62.9 cm³ and 244 cm⁴. But they are from different catalogues (BS EN 10210-2:2006 and EN 10219 · Continental Steel), so this is a design change, not a drop-in swap: re-check deflection, connection detailing and local availability.

RHS 100×75×6, with a second moment of area of 245 cm⁴ against 244 cm⁴ (0.4% more). Deflection under a uniform load goes as 5wL⁴/384EI, so it is inversely proportional to I - on a span where the deflection limit governs rather than strength, this is the number that decides the section.

Related comparisons

RHS 100×50×8 vs RHS 100×75×6RHS 100×60×7.1 vs CF RHS 100×80×6RHS 100×60×7.1 vs RHS 100×50×8
Rate this
No ratings yet
Sign in to join the discussion.
Loading…