CivilAxisCivilAxis
☕ Support🌐 Community

RHS 200×150×8 vs CF RHS 200×120×10

RHS 200×150×8 is an RHS Hot-finished section from the UK Blue Book (SCI P363); CF RHS 200×120×10 is the closest equivalent in the UK Blue Book (SCI P363). They are close to interchangeable in bending: 359 cm³ against 356 cm³ of plastic modulus, a difference of 0.8%. RHS 200×150×8 is the lighter of the two at 41.4 kg/m against 44.4 kg/m, a saving of 6.8% on steel weight. Both are about 200 mm deep, so either fits the same construction zone.

Section properties side by side. Bold marks the more favourable value where one is.
PropertyRHS 200×150×8
RHS Hot-finished
CF RHS 200×120×10
RHS Cold-formed
Difference
Mass41.4 kg/m44.4 kg/m-6.8%
Depth200 mm200 mmsame
Width150 mm120 mm+25.0%
Web thickness0 mm0 mmsame
Flange thickness0 mm0 mmsame
Area52.8 cm²56.6 cm²-6.7%
Second moment, major (Iy)2,970 cm⁴2,810 cm⁴+5.7%
Plastic modulus, major (Wpl,y)359 cm³356 cm³+0.8%
Elastic modulus, major (Wel,y)297 cm³281 cm³+5.7%
Second moment, minor (Iz)1,890 cm⁴1,260 cm⁴+50.0%
Plastic modulus, minor (Wpl,z)294 cm³250 cm³+17.6%
Radius of gyration, minor (iz)5.99 cm4.72 cm+26.9%
Torsion constant (It)3,640 cm⁴3,010 cm⁴+20.9%

RHS 200×150×8 to BS EN 10210-2:2006; CF RHS 200×120×10 to BS EN 10219-2:2006. Difference is expressed relative to CF RHS 200×120×10.

How to choose between them

On stiffness, RHS 200×150×8 has the larger second moment of area: 2,970 cm⁴ against 2,810 cm⁴, a difference of 5.7%. This matters more often than the strength comparison, because on normal floor spans deflection rather than bending capacity sets the beam size - so if the two are close on modulus but apart on inertia, the stiffer one is usually the better answer even when it is not the stronger one.

Measured as bending capacity per kilogram of steel, RHS 200×150×8 is the more efficient section: 8.7 against 8.0 cm³ per kg/m, 8.2% better. Over a floor of repeated beams that difference is real tonnage, though it is often outweighed by whichever section the fabricator can actually source.

The two diverge much more about the minor axis: RHS 200×150×8 has 294 cm³ of minor-axis plastic modulus against 250 cm³, 17.6% more. If the member sees any minor-axis bending, or if it is unrestrained over a long length and lateral-torsional buckling governs, that gap decides the comparison even though the major-axis numbers looked equivalent.

In short, RHS 200×150×8 is the stronger section and RHS 200×150×8 is the lighter one; where those are the same section, it is the clear choice, and where they are not, decide on whether your design is governed by capacity or by tonnage.

Common questions

They are effectively equal in bending. RHS 200×150×8 has a plastic modulus of 359 cm³ and CF RHS 200×120×10 has 356 cm³, a difference of only 0.8% - within the margin that section choice normally turns on. Compare stiffness and availability instead.

RHS 200×150×8 at 41.4 kg/m, against 44.4 kg/m for the other - a saving of 6.8%. Over a repeated floor beam that is a real cost difference, but check it against the deflection case before taking it.

Structurally it is the closest equivalent we hold: CF RHS 200×120×10 gives 356 cm³ of plastic modulus and 2,810 cm⁴ of inertia against 359 cm³ and 2,970 cm⁴. Re-check deflection and the connection details before swapping, since the flange and web thicknesses differ.

RHS 200×150×8, with a second moment of area of 2,970 cm⁴ against 2,810 cm⁴ (5.7% more). Deflection under a uniform load goes as 5wL⁴/384EI, so it is inversely proportional to I - on a span where the deflection limit governs rather than strength, this is the number that decides the section.

Related comparisons

RHS 200×150×8 vs RHS 200×100×12.7
Rate this
No ratings yet
Sign in to join the discussion.