RHS 300×250×10 is an RHS Hot-finished section from the UK Blue Book (SCI P363); RHS 300×200×12.5 is the closest equivalent in the European (Continental) range. They are close to interchangeable in bending: 1100 cm³ against 1091 cm³ of plastic modulus, a difference of 0.8%. RHS 300×250×10 is the lighter of the two at 82.4 kg/m against 88 kg/m, a saving of 6.4% on steel weight. Both are about 300 mm deep, so either fits the same construction zone.

Section properties side by side. Bold marks the more favourable value where one is.
PropertyRHS 300×250×10
RHS Hot-finished
RHS 300×200×12.5
RHS Cold-formed
Difference
Mass82.4 kg/m88 kg/m-6.4%
Depth300 mm300 mmsame
Width250 mm200 mm+25.0%
Web thickness0 mm0 mmsame
Flange thickness0 mm0 mmsame
Area105 cm²112 cm²-6.3%
Second moment, major (Iy)13,900 cm⁴13,180 cm⁴+5.5%
Plastic modulus, major (Wpl,y)1,100 cm³1,091 cm³+0.8%
Elastic modulus, major (Wel,y)928 cm³879 cm³+5.6%
Second moment, minor (Iz)10,500 cm⁴7,060 cm⁴+48.7%
Plastic modulus, minor (Wpl,z)971 cm³828 cm³+17.3%
Radius of gyration, minor (iz)10 cm7.94 cm+25.9%
Torsion constant (It)18,600 cm⁴15,770 cm⁴+17.9%

RHS 300×250×10 to BS EN 10210-2:2006; RHS 300×200×12.5 to EN 10219 · Continental Steel. Difference is expressed relative to RHS 300×200×12.5.

How to choose between them

On stiffness, RHS 300×250×10 has the larger second moment of area: 13,900 cm⁴ against 13,180 cm⁴, a difference of 5.5%. This matters more often than the strength comparison, because on normal floor spans deflection rather than bending capacity sets the beam size - so if the two are close on modulus but apart on inertia, the stiffer one is usually the better answer even when it is not the stronger one.

Measured as bending capacity per kilogram of steel, RHS 300×250×10 is the more efficient section: 13.3 against 12.4 cm³ per kg/m, 7.7% better. Over a floor of repeated beams that difference is real tonnage, though it is often outweighed by whichever section the fabricator can actually source.

The two diverge much more about the minor axis: RHS 300×250×10 has 971 cm³ of minor-axis plastic modulus against 828 cm³, 17.3% more. If the member sees any minor-axis bending, or if it is unrestrained over a long length and lateral-torsional buckling governs, that gap decides the comparison even though the major-axis numbers looked equivalent.

These come from different catalogues, so treat the swap as a design change rather than a like-for-like substitution. RHS Hot-finished sections are specified to BS EN 10210-2:2006 and RHS Cold-formed to EN 10219 · Continental Steel; the steel grades, tolerances and available lengths differ, connection details and bolt gauges are set out differently, and the two are rarely both stocked in the same market. Check availability before changing a section on a drawing to save 6.4% weight.

In short, RHS 300×250×10 is the stronger section and RHS 300×250×10 is the lighter one; where those are the same section, it is the clear choice, and where they are not, decide on whether your design is governed by capacity or by tonnage.

Common questions

They are effectively equal in bending. RHS 300×250×10 has a plastic modulus of 1100 cm³ and RHS 300×200×12.5 has 1091 cm³, a difference of only 0.8% - within the margin that section choice normally turns on. Compare stiffness and availability instead.

RHS 300×250×10 at 82.4 kg/m, against 88 kg/m for the other - a saving of 6.4%. Over a repeated floor beam that is a real cost difference, but check it against the deflection case before taking it.

Structurally it is the closest equivalent we hold: RHS 300×200×12.5 gives 1091 cm³ of plastic modulus and 13,180 cm⁴ of inertia against 1100 cm³ and 13,900 cm⁴. But they are from different catalogues (BS EN 10210-2:2006 and EN 10219 · Continental Steel), so this is a design change, not a drop-in swap: re-check deflection, connection detailing and local availability.

RHS 300×250×10, with a second moment of area of 13,900 cm⁴ against 13,180 cm⁴ (5.5% more). Deflection under a uniform load goes as 5wL⁴/384EI, so it is inversely proportional to I - on a span where the deflection limit governs rather than strength, this is the number that decides the section.