RHS 90×50×3 vs CF RHS 90×50×3

RHS 90×50×3 is an RHS Hot-finished section from the UK Blue Book (SCI P363); CF RHS 90×50×3 is the closest equivalent in the UK Blue Book (SCI P363). RHS 90×50×3 carries more bending: 23.2 cm³ of plastic modulus against 22.6 cm³, 2.7% more. They weigh essentially the same, 6.24 kg/m and 6.13 kg/m. Both are about 90 mm deep, so either fits the same construction zone.

Section properties side by side. Bold marks the more favourable value where one is.
PropertyRHS 90×50×3
RHS Hot-finished
CF RHS 90×50×3
RHS Cold-formed
Difference
Mass6.2 kg/m6.1 kg/m+1.8%
Depth90 mm90 mmsame
Width50 mm50 mmsame
Web thickness0 mm0 mmsame
Flange thickness0 mm0 mmsame
Area7.9 cm²7.8 cm²+1.7%
Second moment, major (Iy)84.4 cm⁴81.9 cm⁴+3.1%
Plastic modulus, major (Wpl,y)23.2 cm³22.6 cm³+2.7%
Elastic modulus, major (Wel,y)18.8 cm³18.2 cm³+3.3%
Second moment, minor (Iz)33.5 cm⁴32.7 cm⁴+2.4%
Plastic modulus, minor (Wpl,z)15.3 cm³15 cm³+2.0%
Radius of gyration, minor (iz)2.05 cm2.05 cmsame
Torsion constant (It)76.5 cm⁴76.7 cm⁴-0.3%

RHS 90×50×3 to BS EN 10210-2:2006; CF RHS 90×50×3 to BS EN 10219-2:2006. Difference is expressed relative to CF RHS 90×50×3.

How to choose between them

On stiffness, RHS 90×50×3 has the larger second moment of area: 84.4 cm⁴ against 81.9 cm⁴, a difference of 3.1%. This matters more often than the strength comparison, because on normal floor spans deflection rather than bending capacity sets the beam size - so if the two are close on modulus but apart on inertia, the stiffer one is usually the better answer even when it is not the stronger one.

Measured as bending capacity per kilogram, the two are equally efficient (3.7 against 3.7 cm³ per kg/m), so on a pure steel-tonnage basis there is nothing to choose between them. The decision comes down to availability, connection detailing and what the rest of the frame uses.

In short, RHS 90×50×3 is the stronger section and CF RHS 90×50×3 is the lighter one; where those are the same section, it is the clear choice, and where they are not, decide on whether your design is governed by capacity or by tonnage.

Common questions

RHS 90×50×3 is the stronger of the two in bending, with a plastic modulus of 23.2 cm³ against 22.6 cm³ - 2.7% more. At the same steel grade that translates directly into moment capacity, since M_pl,Rd = W_pl x f_y / gamma_M0.

Neither meaningfully: RHS 90×50×3 is 6.24 kg/m and CF RHS 90×50×3 is 6.13 kg/m. On a tonnage basis they cost the same.

Structurally it is the closest equivalent we hold: CF RHS 90×50×3 gives 22.6 cm³ of plastic modulus and 81.9 cm⁴ of inertia against 23.2 cm³ and 84.4 cm⁴. Re-check deflection and the connection details before swapping, since the flange and web thicknesses differ.

RHS 90×50×3, with a second moment of area of 84.4 cm⁴ against 81.9 cm⁴ (3.1% more). Deflection under a uniform load goes as 5wL⁴/384EI, so it is inversely proportional to I - on a span where the deflection limit governs rather than strength, this is the number that decides the section.