SHS 50×50×4 vs CF SHS 50×50×4

SHS 50×50×4 is an SHS Hot-finished section from the UK Blue Book (SCI P363); CF SHS 50×50×4 is the closest equivalent in the UK Blue Book (SCI P363). SHS 50×50×4 carries more bending: 12.3 cm³ of plastic modulus against 11.7 cm³, 5.1% more. CF SHS 50×50×4 is the lighter of the two at 5.45 kg/m against 5.64 kg/m, a saving of 3.5% on steel weight. Both are about 50 mm deep, so either fits the same construction zone.

Section properties side by side. Bold marks the more favourable value where one is.
PropertySHS 50×50×4
SHS Hot-finished
CF SHS 50×50×4
SHS Cold-formed
Difference
Mass5.6 kg/m5.5 kg/m+3.5%
Depth50 mm50 mmsame
Width50 mm50 mmsame
Web thickness0 mm0 mmsame
Flange thickness0 mm0 mmsame
Area7.2 cm²7 cm²+3.5%
Second moment, major (Iy)25 cm⁴23.7 cm⁴+5.5%
Plastic modulus, major (Wpl,y)12.3 cm³11.7 cm³+5.1%
Elastic modulus, major (Wel,y)9.99 cm³9.49 cm³+5.3%
Second moment, minor (Iz)25 cm⁴23.7 cm⁴+5.5%
Plastic modulus, minor (Wpl,z)12.3 cm³11.7 cm³+5.1%
Radius of gyration, minor (iz)1.86 cm1.85 cm+0.5%
Torsion constant (It)40.4 cm⁴40.4 cm⁴same

SHS 50×50×4 to BS EN 10210-2:2006; CF SHS 50×50×4 to BS EN 10219-2:2006. Difference is expressed relative to CF SHS 50×50×4.

How to choose between them

On stiffness, SHS 50×50×4 has the larger second moment of area: 25 cm⁴ against 23.7 cm⁴, a difference of 5.5%. This matters more often than the strength comparison, because on normal floor spans deflection rather than bending capacity sets the beam size - so if the two are close on modulus but apart on inertia, the stiffer one is usually the better answer even when it is not the stronger one.

Measured as bending capacity per kilogram, the two are equally efficient (2.2 against 2.1 cm³ per kg/m), so on a pure steel-tonnage basis there is nothing to choose between them. The decision comes down to availability, connection detailing and what the rest of the frame uses.

In short, SHS 50×50×4 is the stronger section and CF SHS 50×50×4 is the lighter one; where those are the same section, it is the clear choice, and where they are not, decide on whether your design is governed by capacity or by tonnage.

Common questions

SHS 50×50×4 is the stronger of the two in bending, with a plastic modulus of 12.3 cm³ against 11.7 cm³ - 5.1% more. At the same steel grade that translates directly into moment capacity, since M_pl,Rd = W_pl x f_y / gamma_M0.

CF SHS 50×50×4 at 5.45 kg/m, against 5.64 kg/m for the other - a saving of 3.5%. Over a repeated floor beam that is a real cost difference, but check it against the deflection case before taking it.

Structurally it is the closest equivalent we hold: CF SHS 50×50×4 gives 11.7 cm³ of plastic modulus and 23.7 cm⁴ of inertia against 12.3 cm³ and 25 cm⁴. Re-check deflection and the connection details before swapping, since the flange and web thicknesses differ.

SHS 50×50×4, with a second moment of area of 25 cm⁴ against 23.7 cm⁴ (5.5% more). Deflection under a uniform load goes as 5wL⁴/384EI, so it is inversely proportional to I - on a span where the deflection limit governs rather than strength, this is the number that decides the section.

Related comparisons

SHS 50×50×3.6 vs CF SHS 50×50×4SHS 50×50×3.6 vs SHS 50×50×4SHS 50×50×4 vs SHS 50×50×4.5
Rate this
No ratings yet
Sign in to join the discussion.