Tee 146×127×19 is an Tees (from UB) section from the UK Blue Book (SCI P363); WT 5X9.5 is the closest equivalent in the American AISC Shapes Database. They are close to interchangeable in bending: 50.7 cm³ against 50.8 cm³ of plastic modulus, a difference of 0.2%. WT 5X9.5 is the lighter of the two at 14.1 kg/m against 18.5 kg/m, a saving of 31.2% on steel weight. Both are about 129 mm deep, so either fits the same construction zone.

Section properties side by side. Bold marks the more favourable value where one is.
PropertyTee 146×127×19
Tees (from UB)
WT 5X9.5
WT
Difference
Mass18.5 kg/m14.1 kg/m+31.2%
Depth127.9 mm130 mm-1.6%
Width146.4 mm102.1 mm+43.4%
Web thickness6.3 mm6.4 mm-1.6%
Flange thickness10.9 mm10 mm+9.0%
Area23.6 cm²18.1 cm²+30.4%
Second moment, major (Iy)292 cm⁴278 cm⁴+5.0%
Plastic modulus, major (Wpl,y)50.7 cm³50.8 cm³-0.2%
Elastic modulus, major (Wel,y)28.5 cm³28.513 cm³same
Second moment, minor (Iz)285 cm⁴89.49 cm⁴+218.5%
Plastic modulus, minor (Wpl,z)59.7 cm³27.366 cm³+118.2%
Radius of gyration, minor (iz)3.48 cm2.22 cm+56.8%
Torsion constant (It)7.65 cm⁴4.83 cm⁴+58.4%

Tee 146×127×19 to BS EN 10365:2017; WT 5X9.5 to AISC Shapes Database v16.0. Difference is expressed relative to WT 5X9.5.

How to choose between them

On stiffness, Tee 146×127×19 has the larger second moment of area: 292 cm⁴ against 278 cm⁴, a difference of 5.0%. This matters more often than the strength comparison, because on normal floor spans deflection rather than bending capacity sets the beam size - so if the two are close on modulus but apart on inertia, the stiffer one is usually the better answer even when it is not the stronger one.

Measured as bending capacity per kilogram of steel, WT 5X9.5 is the more efficient section: 3.6 against 2.7 cm³ per kg/m, 23.9% better. Over a floor of repeated beams that difference is real tonnage, though it is often outweighed by whichever section the fabricator can actually source.

The two diverge much more about the minor axis: Tee 146×127×19 has 59.7 cm³ of minor-axis plastic modulus against 27.366 cm³, 118.2% more. If the member sees any minor-axis bending, or if it is unrestrained over a long length and lateral-torsional buckling governs, that gap decides the comparison even though the major-axis numbers looked equivalent.

These come from different catalogues, so treat the swap as a design change rather than a like-for-like substitution. Tees (from UB) sections are specified to BS EN 10365:2017 and WT to AISC Shapes Database v16.0; the steel grades, tolerances and available lengths differ, connection details and bolt gauges are set out differently, and the two are rarely both stocked in the same market. Check availability before changing a section on a drawing to save 31.2% weight.

In short, WT 5X9.5 is the stronger section and WT 5X9.5 is the lighter one; where those are the same section, it is the clear choice, and where they are not, decide on whether your design is governed by capacity or by tonnage.

Common questions

They are effectively equal in bending. Tee 146×127×19 has a plastic modulus of 50.7 cm³ and WT 5X9.5 has 50.8 cm³, a difference of only 0.2% - within the margin that section choice normally turns on. Compare stiffness and availability instead.

WT 5X9.5 at 14.1 kg/m, against 18.5 kg/m for the other - a saving of 31.2%. Over a repeated floor beam that is a real cost difference, but check it against the deflection case before taking it.

Structurally it is the closest equivalent we hold: WT 5X9.5 gives 50.8 cm³ of plastic modulus and 278 cm⁴ of inertia against 50.7 cm³ and 292 cm⁴. But they are from different catalogues (BS EN 10365:2017 and AISC Shapes Database v16.0), so this is a design change, not a drop-in swap: re-check deflection, connection detailing and local availability.

Tee 146×127×19, with a second moment of area of 292 cm⁴ against 278 cm⁴ (5.0% more). Deflection under a uniform load goes as 5wL⁴/384EI, so it is inversely proportional to I - on a span where the deflection limit governs rather than strength, this is the number that decides the section.