CivilAxisCivilAxis
☕ Support🌐 Community

Tee 191×229×81 vs ST 10X43

Tee 191×229×81 is an Tees (from UB) section from the UK Blue Book (SCI P363); ST 10X43 is the closest equivalent in the American AISC Shapes Database. They are close to interchangeable in bending: 507 cm³ against 509.64 cm³ of plastic modulus, a difference of 0.5%. ST 10X43 is the lighter of the two at 64 kg/m against 80.7 kg/m, a saving of 26.1% on steel weight. ST 10X43 is deeper, 259.1 mm against 246 mm, which matters where the floor zone is tight.

Section properties side by side. Bold marks the more favourable value where one is.
PropertyTee 191×229×81
Tees (from UB)
ST 10X43
ST
Difference
Mass80.7 kg/m64 kg/m+26.1%
Depth246 mm259.1 mm-5.1%
Width199.4 mm179.3 mm+11.2%
Web thickness18 mm16.8 mm+7.1%
Flange thickness32 mm23.4 mm+36.8%
Area103 cm²81.9 cm²+25.8%
Second moment, major (Iy)5,160 cm⁴5,161 cm⁴same
Plastic modulus, major (Wpl,y)507 cm³509.64 cm³-0.5%
Elastic modulus, major (Wel,y)281 cm³281.86 cm³-0.3%
Second moment, minor (Iz)2,130 cm⁴969.8 cm⁴+119.6%
Plastic modulus, minor (Wpl,z)336 cm³190.09 cm³+76.8%
Radius of gyration, minor (iz)4.55 cm3.45 cm+31.9%
Torsion constant (It)256 cm⁴137.4 cm⁴+86.3%

Tee 191×229×81 to BS EN 10365:2017; ST 10X43 to AISC Shapes Database v16.0. Difference is expressed relative to ST 10X43.

How to choose between them

On stiffness, ST 10X43 has the larger second moment of area: 5,161 cm⁴ against 5,160 cm⁴, a difference of 0.0%. This matters more often than the strength comparison, because on normal floor spans deflection rather than bending capacity sets the beam size - so if the two are close on modulus but apart on inertia, the stiffer one is usually the better answer even when it is not the stronger one.

Measured as bending capacity per kilogram of steel, ST 10X43 is the more efficient section: 8.0 against 6.3 cm³ per kg/m, 21.1% better. Over a floor of repeated beams that difference is real tonnage, though it is often outweighed by whichever section the fabricator can actually source.

The two diverge much more about the minor axis: Tee 191×229×81 has 336 cm³ of minor-axis plastic modulus against 190.09 cm³, 76.8% more. If the member sees any minor-axis bending, or if it is unrestrained over a long length and lateral-torsional buckling governs, that gap decides the comparison even though the major-axis numbers looked equivalent.

These come from different catalogues, so treat the swap as a design change rather than a like-for-like substitution. Tees (from UB) sections are specified to BS EN 10365:2017 and ST to AISC Shapes Database v16.0; the steel grades, tolerances and available lengths differ, connection details and bolt gauges are set out differently, and the two are rarely both stocked in the same market. Check availability before changing a section on a drawing to save 26.1% weight.

In short, ST 10X43 is the stronger section and ST 10X43 is the lighter one; where those are the same section, it is the clear choice, and where they are not, decide on whether your design is governed by capacity or by tonnage.

Common questions

They are effectively equal in bending. Tee 191×229×81 has a plastic modulus of 507 cm³ and ST 10X43 has 509.64 cm³, a difference of only 0.5% - within the margin that section choice normally turns on. Compare stiffness and availability instead.

ST 10X43 at 64 kg/m, against 80.7 kg/m for the other - a saving of 26.1%. Over a repeated floor beam that is a real cost difference, but check it against the deflection case before taking it.

Structurally it is the closest equivalent we hold: ST 10X43 gives 509.64 cm³ of plastic modulus and 5,161 cm⁴ of inertia against 507 cm³ and 5,160 cm⁴. But they are from different catalogues (BS EN 10365:2017 and AISC Shapes Database v16.0), so this is a design change, not a drop-in swap: re-check deflection, connection detailing and local availability.

ST 10X43, with a second moment of area of 5,161 cm⁴ against 5,160 cm⁴ (0.0% more). Deflection under a uniform load goes as 5wL⁴/384EI, so it is inversely proportional to I - on a span where the deflection limit governs rather than strength, this is the number that decides the section.

Related comparisons

Tee 210×267×69 vs ST 10X43Tee 191×229×81 vs WT 9X65WT 10.5X55.5 vs ST 10X43WT 10.5X46.5 vs ST 10X43WT 9X65 vs ST 10X43
Rate this
No ratings yet
Sign in to join the discussion.
Loading…