UB 1016×305×349 vs HE 1000 M
UB 1016×305×349 is an UB section from the UK Blue Book (SCI P363); HE 1000 M is the closest equivalent in the European (Continental) range. They are close to interchangeable in bending: 16600 cm³ against 16600 cm³ of plastic modulus, a difference of 0.0%. They weigh essentially the same, 349.4 kg/m and 349 kg/m. Both are about 1008 mm deep, so either fits the same construction zone.
| Property | UB 1016×305×349 UB | HE 1000 M HE | Difference |
|---|---|---|---|
| Mass | 349.4 kg/m | 349 kg/m | +0.1% |
| Depth | 1008.1 mm | 1008 mm | same |
| Width | 302 mm | 302 mm | same |
| Web thickness | 21.1 mm | 21 mm | +0.5% |
| Flange thickness | 40 mm | 40 mm | same |
| Area | 445 cm² | 444 cm² | +0.2% |
| Second moment, major (Iy) | 723,000 cm⁴ | 722,000 cm⁴ | +0.1% |
| Plastic modulus, major (Wpl,y) | 16,600 cm³ | 16,600 cm³ | same |
| Elastic modulus, major (Wel,y) | 14,300 cm³ | 14,300 cm³ | same |
| Second moment, minor (Iz) | 18,500 cm⁴ | 18,500 cm⁴ | same |
| Plastic modulus, minor (Wpl,z) | 1,940 cm³ | 1,940 cm³ | same |
| Radius of gyration, minor (iz) | 6.44 cm | 6.45 cm | -0.2% |
| Torsion constant (It) | 1,720 cm⁴ | 1,710 cm⁴ | +0.6% |
UB 1016×305×349 to BS EN 10365:2017; HE 1000 M to EN 10365 · Continental Steel. Difference is expressed relative to HE 1000 M.
How to choose between them
On stiffness, UB 1016×305×349 has the larger second moment of area: 723,000 cm⁴ against 722,000 cm⁴, a difference of 0.1%. This matters more often than the strength comparison, because on normal floor spans deflection rather than bending capacity sets the beam size - so if the two are close on modulus but apart on inertia, the stiffer one is usually the better answer even when it is not the stronger one.
Measured as bending capacity per kilogram, the two are equally efficient (47.5 against 47.6 cm³ per kg/m), so on a pure steel-tonnage basis there is nothing to choose between them. The decision comes down to availability, connection detailing and what the rest of the frame uses.
These come from different catalogues, so treat the swap as a design change rather than a like-for-like substitution. UB sections are specified to BS EN 10365:2017 and HE to EN 10365 · Continental Steel; the steel grades, tolerances and available lengths differ, connection details and bolt gauges are set out differently, and the two are rarely both stocked in the same market. Check availability before changing a section on a drawing to save a marginal amount of weight.
In short, these two are genuine equivalents. Pick whichever your supplier stocks and the rest of the frame already uses.