HSS 10.750X0.375 - Section Properties
The HSS 10.750X0.375 is a steel section with a mass of 61.9 kg/m, an overall depth of 274.3 mm and width of 274.3 mm and a wall thickness of 8.9 mm. It has a cross-sectional area of 73.5 cm², a second moment of area Iᵧ of 6410 cm⁴, a plastic modulus Wₚₗ,ᵧ of 619.43 cm³, tabulated by CivilAxis from AISC Shapes Database v16.0.
Ask about capacity, buckling or detailing for HSS 10.750X0.375.
or pick a unit on any row

Dimension symbols for HSS sections. Not to scale.
Is HSS 10.750X0.375 strong enough?
Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.
✅Passes - 58% utilised, deflection governs
Bending26%
56.7 / 219.9 kNmShear5%
41.3 / 753.2 kNDeflection58%
8.9 / 15.3 mmClass 2 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.