HSS 11.750X0.375 - Section Properties
The HSS 11.750X0.375 is a steel section with a mass of 67.9 kg/m, an overall depth of 299.7 mm and width of 299.7 mm and a wall thickness of 8.9 mm. It has a cross-sectional area of 80.6 cm², a second moment of area Iᵧ of 8449 cm⁴, a plastic modulus Wₚₗ,ᵧ of 742.33 cm³, tabulated by CivilAxis from AISC Shapes Database v16.0.
Ask about capacity, buckling or detailing for HSS 11.750X0.375.
or pick a unit on any row

Dimension symbols for HSS sections. Not to scale.
Is HSS 11.750X0.375 strong enough?
Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.
✅Passes - 63% utilised, deflection governs
Bending28%
74.3 / 263.5 kNmShear6%
49.5 / 826.0 kNDeflection63%
10.5 / 16.7 mmClass 2 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.
Common questions about HSS 11.750X0.375
Related HSS sizes
Learn more
Rate thisNo ratings yet
Sign in to join the discussion.