HSS 24X12X5-8 - Section Properties
The HSS 24X12X5-8 is a steel section with a mass of 214.9 kg/m, an overall depth of 609.6 mm and width of 304.8 mm and a wall thickness of 14.8 mm. It has a cross-sectional area of 255.5 cm², a second moment of area Iᵧ of 122372 cm⁴, a plastic modulus Wₚₗ,ᵧ of 4981.7 cm³, tabulated by CivilAxis from AISC Shapes Database v16.0.
Ask about capacity, buckling or detailing for HSS 24X12X5-8.
or pick a unit on any row

Dimension symbols for HSS sections. Not to scale.
Is HSS 24X12X5-8 strong enough?
Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.
✅Passes - 60% utilised, deflection governs
Bending29%
513.0 / 1768.5 kNmShear5%
171.0 / 3491.1 kNDeflection60%
20.0 / 33.3 mmClass 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.
Common questions about HSS 24X12X5-8
Related HSS sizes
Learn more
Rate thisNo ratings yet
Sign in to join the discussion.