CivilAxisCivilAxis
☕ Support🌐 Community

HSS 3.500X0.250 - Section Properties

The HSS 3.500X0.250 is a steel section with a mass of 12.9 kg/m, an overall depth of 88.9 mm and width of 88.9 mm and a wall thickness of 5.9 mm. It has a cross-sectional area of 15.4 cm², a second moment of area Iᵧ of 133.6 cm⁴, a plastic modulus Wₚₗ,ᵧ of 40.804 cm³, tabulated by CivilAxis from AISC Shapes Database v16.0.

Mass
8.69 lb/ft (12.9 kg/m)
Depth
3.5 in (88.9 mm)
Width
3.5 in (88.9 mm)
Wall thickness
0.233 in (5.9 mm)
Area
2.39 in² (15.4 cm²)
Ask about capacity, buckling or detailing for HSS 3.500X0.250.
🔍 Open the full Steel Catalogue
or pick a unit on any row
HSS section profile showing the dimension symbols used for HSS 3.500X0.250

Dimension symbols for HSS sections. Not to scale.

HSS 3.500X0.250 section properties to AISC Shapes Database v16.0.

Geometry

Depth of sectionh3.5
88.9 mm
Width of sectionb3.5
88.9 mm
Web thicknesstw0.233
5.9 mm
Wall thicknesst0.233
5.9 mm

Mass and area

Mass per metremass8.69
12.9 kg/m
Cross-sectional areaA2.39
15.4 cm²

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy3.21
133.6 cm⁴
Elastic section modulus about y-axisWel,y1.83
29.988 cm³
Plastic section modulus about y-axisWpl,y2.49
40.804 cm³
Radius of gyration about y-axisiy1.16
2.95 cm

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz3.21
133.6 cm⁴
Elastic section modulus about z-axisWel,z1.83
29.988 cm³
Plastic section modulus about z-axisWpl,z2.49
40.804 cm³
Radius of gyration about z-axisiz1.16
2.95 cm

Torsion and warping

Torsion constant (St Venant)It6.41
266.8 cm⁴

Is HSS 3.500X0.250 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 60% utilised, deflection governs
Bending23%
3.4 / 14.5 kNm
Shear4%
6.8 / 157.8 kN
Deflection60%
3.3 / 5.6 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about HSS 3.500X0.250

HSS 3.500X0.250 has a mass of 8.69 lb/ft (12.9 kg/m), tabulated to AISC Shapes Database v16.0. A 12 m length therefore weighs about 155 kg, which is the figure to use for a steel take-off or when checking a lift.

HSS 3.500X0.250 has a depth of 3.5 in (88.9 mm), a width of 3.5 in (88.9 mm), a web thickness of 0.233 in (5.9 mm), a wall thickness of 0.233 in (5.9 mm), with a cross-sectional area of 2.39 in² (15.4 cm²). These are the nominal dimensions from AISC Shapes Database v16.0; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 40.804 cm³, and the elastic modulus Wel,y is 29.988 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 14 kNm before any stability check.

The second moment of area about the major axis, Iy, is 133.6 cm⁴, and about the minor axis Iz is 133.6 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

iy is 2.95 cm about the major axis and iz is 2.95 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 2.95 cm a 0.3 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 266.8 cm⁴. Closed sections carry torsion in a shear flow around the perimeter, which makes them far stiffer in torsion than an open section of the same weight and is usually why one is specified.

Related HSS sizes

HSS 4.000X0.188HSS 4.000X0.125HSS 3.500X0.313HSS 3.500X0.300HSS 3.500X0.216HSS 3.500X0.203HSS 3.500X0.188HSS 3.500X0.125

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 SHS vs RHS vs CHS: choosing a hollow steel section
All HSS sizes
AISC HSS (Hollow Structural Sections)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…