CivilAxisCivilAxis
☕ Support🌐 Community

PFC 150×90 - Section Properties

The PFC 150×90 is a steel section with a mass of 23.9 kg/m, an overall depth of 150 mm and width of 90 mm. It has a cross-sectional area of 30.4 cm², a second moment of area Iᵧ of 1162 cm⁴, a plastic modulus Wₚₗ,ᵧ of 179 cm³, tabulated by CivilAxis from Continental Steel.

Mass
23.9 kg/m
Depth
150 mm
Width
90 mm
Area
30.4 cm²
Ask about capacity, buckling or detailing for PFC 150×90.
🔍 Open the full Steel Catalogue
or pick a unit on any row
PFC section profile showing the dimension symbols used for PFC 150×90

Dimension symbols for PFC sections. Not to scale.

PFC 150×90 section properties to Continental Steel.

Geometry

Depth of sectionh150
Width of sectionb90
Web thicknesstw6.5
Flange thicknesstf12
Root fillet radiusr12
Depth between filletsd102

Mass and area

Mass per metremass23.9
Cross-sectional areaA30.4

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy1162
Elastic section modulus about y-axisWel,y155
Plastic section modulus about y-axisWpl,y179
Radius of gyration about y-axisiy6.18

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz253
Elastic section modulus about z-axisWel,z44.4
Plastic section modulus about z-axisWpl,z76.9
Radius of gyration about z-axisiz2.89

Torsion and warping

Torsion constant (St Venant)It11.8
Warping constantIw0.009

Classification and stability

Flange local-buckling ratiocf/tf7.5
Web local-buckling ratiocw/tw15.7
Buckling parameteru0.936
Torsional indexX10.8

Detailing dimensions

Centroid distance from back of leg (y)cy3.3

Is PFC 150×90 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 62% utilised, deflection governs
Bending32%
20.3 / 63.5 kNm
Shear12%
27.0 / 225.9 kN
Deflection62%
5.2 / 8.3 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about PFC 150×90

PFC 150×90 has a mass of 23.9 kg/m, tabulated to Continental Steel. A 12 m length therefore weighs about 287 kg, which is the figure to use for a steel take-off or when checking a lift.

PFC 150×90 has a depth of 150 mm, a width of 90 mm, a web thickness of 6.5 mm, a flange thickness of 12 mm, with a cross-sectional area of 30.4 cm². These are the nominal dimensions from Continental Steel; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 179 cm³, and the elastic modulus Wel,y is 155 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 64 kNm before any stability check.

The second moment of area about the major axis, Iy, is 1,162 cm⁴, and about the minor axis Iz is 253 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 7.5 for the flange and cw/tw = 15.7 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 6.18 cm about the major axis and iz is 2.89 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 2.89 cm a 0.3 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 11.8 cm⁴. Closed sections carry torsion in a shear flow around the perimeter, which makes them far stiffer in torsion than an open section of the same weight and is usually why one is specified.

Related PFC sizes

PFC 100×50PFC 125×65PFC 150×75PFC 180×75PFC 180×90PFC 200×75PFC 200×90PFC 230×75

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs PFC 150×90×24

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)