CivilAxisCivilAxis
☕ Support🌐 Community

RHS 200×150×10 - Section Properties

The RHS 200×150×10 is a steel section with a mass of 51.4 kg/m, an overall depth of 200 mm and width of 150 mm and a wall thickness of 10 mm. It has a cross-sectional area of 64.9 cm², a second moment of area Iᵧ of 3568 cm⁴, a plastic modulus Wₚₗ,ᵧ of 436 cm³, tabulated by CivilAxis from EN 10219 · Continental Steel.

Mass
51.4 kg/m
Depth
200 mm
Width
150 mm
Wall thickness
10 mm
Area
64.9 cm²
Ask about capacity, buckling or detailing for RHS 200×150×10.
🔍 Open the full Steel Catalogue
or pick a unit on any row
RHS section profile showing the dimension symbols used for RHS 200×150×10

Dimension symbols for RHS sections. Not to scale.

RHS 200×150×10 section properties to EN 10219 · Continental Steel.

Geometry

Depth of sectionh200
Width of sectionb150
Wall thicknesst10

Mass and area

Mass per metremass51.4
Cross-sectional areaA64.9

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy3568
Elastic section modulus about y-axisWel,y357
Plastic section modulus about y-axisWpl,y436
Radius of gyration about y-axisiy7.41

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz2264
Elastic section modulus about z-axisWel,z302
Plastic section modulus about z-axisWpl,z356
Radius of gyration about z-axisiz5.91

Torsion and warping

Torsion constant (St Venant)It4409
Section modulus for torsionWt475

Surface area

Surface area per metreSA/m0.674

Is RHS 200×150×10 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 60% utilised, deflection governs
Bending29%
45.0 / 154.8 kNm
Shear6%
45.0 / 760.1 kN
Deflection60%
6.7 / 11.1 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about RHS 200×150×10

RHS 200×150×10 has a mass of 51.4 kg/m, tabulated to EN 10219. A 12 m length therefore weighs about 617 kg, which is the figure to use for a steel take-off or when checking a lift.

RHS 200×150×10 has a depth of 200 mm, a width of 150 mm, a wall thickness of 10 mm, with a cross-sectional area of 64.9 cm². These are the nominal dimensions from EN 10219; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 436 cm³, and the elastic modulus Wel,y is 357 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 155 kNm before any stability check.

The second moment of area about the major axis, Iy, is 3,568 cm⁴, and about the minor axis Iz is 2,264 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

iy is 7.41 cm about the major axis and iz is 5.91 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 5.91 cm a 0.6 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 4,409 cm⁴. Closed sections carry torsion in a shear flow around the perimeter, which makes them far stiffer in torsion than an open section of the same weight and is usually why one is specified.

Related RHS sizes

RHS 200×150×6RHS 200×150×6.3RHS 200×150×8RHS 200×150×9RHS 200×150×12RHS 200×150×12.5RHS 250×150×6RHS 250×150×6.3

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs RHS 200×100×14.2vs RHS 200×120×12.5

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 SHS vs RHS vs CHS: choosing a hollow steel section
All RHS sizes
Rectangular Hollow Sections (RHS)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…