RHS 400×200×16 - Section Properties
The RHS 400×200×16 is a steel section with a mass of 142 kg/m, an overall depth of 400 mm and width of 200 mm and a wall thickness of 16 mm. It has a cross-sectional area of 179 cm², a second moment of area Iᵧ of 35740 cm⁴, a plastic modulus Wₚₗ,ᵧ of 2256 cm³, tabulated by CivilAxis from EN 10219 · Continental Steel.
Ask about capacity, buckling or detailing for RHS 400×200×16.
or pick a unit on any row

Dimension symbols for RHS sections. Not to scale.
Is RHS 400×200×16 strong enough?
Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.
✅Passes - 61% utilised, deflection governs
Bending28%
228.0 / 800.9 kNmShear5%
114.0 / 2445.8 kNDeflection61%
13.5 / 22.2 mmClass 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.
Common questions about RHS 400×200×16
Related RHS sizes
Learn more
Rate thisNo ratings yet
Sign in to join the discussion.