RHS 90×50×6 - Section Properties
The RHS 90×50×6 is a steel section with a mass of 11.9 kg/m, an overall depth of 90 mm and width of 50 mm and a wall thickness of 6 mm. It has a cross-sectional area of 15 cm², a second moment of area Iᵧ of 145 cm⁴, a plastic modulus Wₚₗ,ᵧ of 41.6 cm³, tabulated by CivilAxis from EN 10219 · Continental Steel.
Ask about capacity, buckling or detailing for RHS 90×50×6.
or pick a unit on any row

Dimension symbols for RHS sections. Not to scale.
Is RHS 90×50×6 strong enough?
Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.
✅Passes - 62% utilised, deflection governs
Bending25%
3.8 / 14.8 kNmShear4%
7.5 / 197.6 kNDeflection62%
3.4 / 5.6 mmClass 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.