SHS 16×16×1.6 - Section Properties
The SHS 16×16×1.6 is a steel section with a mass of 0.699 kg/m, an overall depth of 16 mm and width of 16 mm and a wall thickness of 1.6 mm. It has a cross-sectional area of 0.856 cm², a second moment of area Iᵧ of 0.284 cm⁴, a plastic modulus Wₚₗ,ᵧ of 0.449 cm³, tabulated by CivilAxis from EN 10219 · Continental Steel.
Ask about capacity, buckling or detailing for SHS 16×16×1.6.
or pick a unit on any row

Dimension symbols for SHS Cold-formed sections. Not to scale.
Is SHS 16×16×1.6 strong enough?
Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.
✅Passes - 59% utilised, deflection governs
Bending18%
0.0 / 0.2 kNmShear3%
0.2 / 8.8 kNDeflection59%
0.8 / 1.4 mmClass 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.
Common questions about SHS 16×16×1.6
Related SHS Cold-formed sizes
Learn more
Rate thisNo ratings yet
Sign in to join the discussion.
Loading…