SHS 60×60×6 - Section Properties
The SHS 60×60×6 is a steel section with a mass of 9.44 kg/m, an overall depth of 60 mm and width of 60 mm and a wall thickness of 6 mm. It has a cross-sectional area of 12 cm², a second moment of area Iᵧ of 56.1 cm⁴, a plastic modulus Wₚₗ,ᵧ of 23.7 cm³, tabulated by CivilAxis from EN 10219 · Continental Steel.
Ask about capacity, buckling or detailing for SHS 60×60×6.
or pick a unit on any row

Dimension symbols for SHS Cold-formed sections. Not to scale.
Is SHS 60×60×6 strong enough?
Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.
✅Passes - 60% utilised, deflection governs
Bending33%
2.8 / 8.4 kNmShear9%
11.3 / 123.0 kNDeflection60%
1.7 / 2.8 mmClass 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.
Common questions about SHS 60×60×6
Related SHS Cold-formed sizes
Learn more
Rate thisNo ratings yet
Sign in to join the discussion.
Loading…