SHS 75×75×3 - Section Properties
The SHS 75×75×3 is a steel section with a mass of 6.81 kg/m, an overall depth of 75 mm and width of 75 mm and a wall thickness of 3 mm. It has a cross-sectional area of 8.41 cm², a second moment of area Iᵧ of 71.6 cm⁴, a plastic modulus Wₚₗ,ᵧ of 22.5 cm³, tabulated by CivilAxis from EN 10219 · Continental Steel.
Ask about capacity, buckling or detailing for SHS 75×75×3.
or pick a unit on any row

Dimension symbols for SHS Cold-formed sections. Not to scale.
Is SHS 75×75×3 strong enough?
Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.
✅Passes - 58% utilised, deflection governs
Bending29%
2.3 / 8.0 kNmShear7%
6.2 / 86.2 kNDeflection58%
2.4 / 4.2 mmClass 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.
Common questions about SHS 75×75×3
Related SHS Cold-formed sizes
Learn more
Rate thisNo ratings yet
Sign in to join the discussion.