SHS 100×100×5 - Section Properties
The SHS 100×100×5 is a steel section with a mass of 14.8 kg/m, an overall depth of 100 mm and width of 100 mm and a wall thickness of 5 mm. It has a cross-sectional area of 18.7 cm², a second moment of area Iᵧ of 279 cm⁴, a plastic modulus Wₚₗ,ᵧ of 66.4 cm³, tabulated by CivilAxis from EN 10219 · Continental Steel.
Ask about capacity, buckling or detailing for SHS 100×100×5.
or pick a unit on any row

Dimension symbols for SHS sections. Not to scale.
Is SHS 100×100×5 strong enough?
Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.
✅Passes - 61% utilised, deflection governs
Bending30%
7.1 / 23.6 kNmShear7%
14.3 / 191.6 kNDeflection61%
3.4 / 5.6 mmClass 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.
Common questions about SHS 100×100×5
Related SHS sizes
Learn more
Rate thisNo ratings yet
Sign in to join the discussion.
Loading…