SHS 150×150×8 - Section Properties
The SHS 150×150×8 is a steel section with a mass of 35.4 kg/m, an overall depth of 150 mm and width of 150 mm and a wall thickness of 8 mm. It has a cross-sectional area of 44.8 cm², a second moment of area Iᵧ of 1491 cm⁴, a plastic modulus Wₚₗ,ᵧ of 237 cm³, tabulated by CivilAxis from EN 10219 · Continental Steel.
Ask about capacity, buckling or detailing for SHS 150×150×8.
or pick a unit on any row

Dimension symbols for SHS sections. Not to scale.
Is SHS 150×150×8 strong enough?
Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.
✅Passes - 61% utilised, deflection governs
Bending30%
25.3 / 84.1 kNmShear7%
33.8 / 459.1 kNDeflection61%
5.1 / 8.3 mmClass 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.