SHS 25×25×2 - Section Properties
The SHS 25×25×2 is a steel section with a mass of 1.41 kg/m, an overall depth of 25 mm and width of 25 mm and a wall thickness of 2 mm. It has a cross-sectional area of 1.8 cm², a second moment of area Iᵧ of 1.56 cm⁴, a plastic modulus Wₚₗ,ᵧ of 1.53 cm³, tabulated by CivilAxis from EN 10219 · Continental Steel.
Ask about capacity, buckling or detailing for SHS 25×25×2.
or pick a unit on any row

Dimension symbols for SHS sections. Not to scale.
Is SHS 25×25×2 strong enough?
Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.
✅Passes - 63% utilised, deflection governs
Bending30%
0.2 / 0.5 kNmShear7%
1.3 / 18.4 kNDeflection63%
0.9 / 1.4 mmClass 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.