CivilAxisCivilAxis
☕ Support🌐 Community

SHS 60×60×6.3 - Section Properties

The SHS 60×60×6.3 is a steel section with a mass of 10.5 kg/m, an overall depth of 60 mm and width of 60 mm and a wall thickness of 6.3 mm. It has a cross-sectional area of 13.1 cm², a second moment of area Iᵧ of 61.6 cm⁴, a plastic modulus Wₚₗ,ᵧ of 26 cm³, tabulated by CivilAxis from EN 10219 · Continental Steel.

Mass
10.5 kg/m
Depth
60 mm
Width
60 mm
Wall thickness
6.3 mm
Area
13.1 cm²
Ask about capacity, buckling or detailing for SHS 60×60×6.3.
🔍 Open the full Steel Catalogue
or pick a unit on any row
SHS section profile showing the dimension symbols used for SHS 60×60×6.3

Dimension symbols for SHS sections. Not to scale.

SHS 60×60×6.3 section properties to EN 10219 · Continental Steel.

Geometry

Depth of sectionh60
Width of sectionb60
Wall thicknesst6.3

Mass and area

Mass per metremass10.5
Cross-sectional areaA13.1

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy61.6
Elastic section modulus about y-axisWel,y20.5
Plastic section modulus about y-axisWpl,y26
Radius of gyration about y-axisiy2.17

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz61.6
Elastic section modulus about z-axisWel,z20.5
Plastic section modulus about z-axisWpl,z26
Radius of gyration about z-axisiz2.17

Torsion and warping

Torsion constant (St Venant)It102
Section modulus for torsionWt29.6

Surface area

Surface area per metreSA/m0.224

Is SHS 60×60×6.3 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 62% utilised, deflection governs
Bending35%
3.2 / 9.2 kNm
Shear9%
12.8 / 134.2 kN
Deflection62%
1.7 / 2.8 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about SHS 60×60×6.3

SHS 60×60×6.3 has a mass of 10.5 kg/m, tabulated to EN 10219. A 12 m length therefore weighs about 126 kg, which is the figure to use for a steel take-off or when checking a lift.

SHS 60×60×6.3 has a depth of 60 mm, a width of 60 mm, a wall thickness of 6.3 mm, with a cross-sectional area of 13.1 cm². These are the nominal dimensions from EN 10219; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 26 cm³, and the elastic modulus Wel,y is 20.5 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 9 kNm before any stability check.

The second moment of area about the major axis, Iy, is 61.6 cm⁴, and about the minor axis Iz is 61.6 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

iy is 2.17 cm about the major axis and iz is 2.17 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 2.17 cm a 0.2 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 102 cm⁴. Closed sections carry torsion in a shear flow around the perimeter, which makes them far stiffer in torsion than an open section of the same weight and is usually why one is specified.

Related SHS sizes

SHS 60×60×3.2SHS 60×60×4SHS 60×60×5SHS 60×60×6SHS 60×60×8SHS 60×60×10SHS 70×70×3SHS 70×70×3.6

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 SHS vs RHS vs CHS: choosing a hollow steel section