CivilAxisCivilAxis
☕ Support🌐 Community

IPE AA 160 - Section Properties

The IPE AA 160 is a European I-beam (IPE) with a mass of 12.3 kg/m, an overall depth of 156.4 mm and width of 82 mm. It has a cross-sectional area of 15.7 cm², a second moment of area Iᵧ of 659 cm⁴, a plastic modulus Wₚₗ,ᵧ of 95.2 cm³, tabulated by CivilAxis from EN 10365 · Continental Steel.

Mass
12.3 kg/m
Depth
156.4 mm
Width
82 mm
Area
15.7 cm²
Ask about capacity, buckling or detailing for IPE AA 160.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
IPE section profile showing the dimension symbols used for IPE AA 160

Dimension symbols for IPE sections. Not to scale.

IPE AA 160 section properties to EN 10365 · Continental Steel.

Geometry

Depth of sectionh156.4
Width of sectionb82
Web thicknesstw4
Flange thicknesstf5.6
Root fillet radiusr9
Depth between filletsd131.2

Mass and area

Mass per metremass12.3
Cross-sectional areaA15.7

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy659
Elastic section modulus about y-axisWel,y84.3
Plastic section modulus about y-axisWpl,y95.2
Radius of gyration about y-axisiy6.48

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz51.7
Elastic section modulus about z-axisWel,z13
Plastic section modulus about z-axisWpl,z19.7
Radius of gyration about z-axisiz1.81

Torsion and warping

Torsion constant (St Venant)It1.75
Warping constantIw0.00293

Classification and stability

Flange local-buckling ratiocf/tf5.36
Web local-buckling ratiocw/tw32.8
Buckling parameteru4.038
Torsional indexX25.5

Detailing dimensions

End clearanceC4
Notch dimension NN50
Notch dimension nn14

Surface area

Surface area per metreSA/m0.625

Is IPE AA 160 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 59% utilised, deflection governs
Bending32%
11.0 / 33.8 kNm
Shear9%
14.6 / 158.8 kN
Deflection59%
5.0 / 8.3 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about IPE AA 160

IPE AA 160 has a mass of 12.3 kg/m, tabulated to EN 10365. A 12 m length therefore weighs about 148 kg, which is the figure to use for a steel take-off or when checking a lift.

IPE AA 160 has a depth of 156.4 mm, a width of 82 mm, a web thickness of 4 mm, a flange thickness of 5.6 mm, with a cross-sectional area of 15.7 cm². These are the nominal dimensions from EN 10365; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 95.2 cm³, and the elastic modulus Wel,y is 84.3 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 34 kNm before any stability check.

The second moment of area about the major axis, Iy, is 659 cm⁴, and about the minor axis Iz is 51.7 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 5.36 for the flange and cw/tw = 32.8 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 6.48 cm about the major axis and iz is 1.81 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 1.81 cm a 0.2 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 1.75 cm⁴, and the warping constant Iw is 0.00293 dm⁶. Open sections carry torsion mainly by warping rather than uniform torsion, which is why Iw appears in the lateral-torsional buckling resistance - both values feed M_b,Rd.

Related IPE sizes

IPE 120IPE AA 140IPE A 140IPE 140IPE A 160IPE 160IPE AA 180IPE A 180

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 IPE vs HE (HEA/HEB): choosing a European steel beam
All IPE sizes
European I-Beams (IPE)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…