IPE V 500 - Section Properties
The IPE V 500 is a European I-beam (IPE) with a mass of 129 kg/m, an overall depth of 514 mm and width of 204 mm. It has a cross-sectional area of 164 cm², a second moment of area Iᵧ of 70700 cm⁴, a plastic modulus Wₚₗ,ᵧ of 3170 cm³, tabulated by CivilAxis from EN 10365 · Continental Steel.
Ask about capacity, buckling or detailing for IPE V 500.
or pick a unit on any row

Dimension symbols for IPE sections. Not to scale.
Is IPE V 500 strong enough?
Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.
✅Passes - 58% utilised, deflection governs
Bending29%
330.8 / 1125.3 kNmShear7%
126.0 / 1702.9 kNDeflection58%
17.1 / 29.2 mmClass 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.