UA 70×50×6 BtB - Section Properties

The UA 70×50×6 BtB is a unequal angle with a mass of 10.8 kg/m. It has a cross-sectional area of 13.8 cm², a second moment of area Iᵧ of 66.8 cm⁴, an elastic modulus Wₑₗ,ᵧ of 14 cm³, tabulated by CivilAxis from BS EN 1993-1-1:2005 / BS EN 10056-1:1999 (SCI P363 Blue Book).

Mass
10.8 kg/m
Area
13.8 cm²
Ask about capacity, buckling or detailing for UA 70×50×6 BtB.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
UA Back to Back section profile showing the dimension symbols used for UA 70×50×6 BtB

Dimension symbols for UA Back to Back sections. Not to scale.

UA 70×50×6 BtB section properties to BS EN 1993-1-1:2005 / BS EN 10056-1:1999.

Mass and area

Mass per metremass10.8
Cross-sectional areaA13.8

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy66.8
Elastic section modulus about y-axisWel,y14
Radius of gyration about y-axisiy2.2

Bending about the minor axis (z-z)

Radius of gyration about z-axisiz1.9

Detailing dimensions

Centroid distance from back of leg (y)cy4.77
Centroid distance from back of leg (z)cz4.77

Common questions about UA 70×50×6 BtB

UA 70×50×6 BtB has a mass of 10.8 kg/m, tabulated to BS EN 1993-1-1:2005 / BS EN 10056-1:1999. A 12 m length therefore weighs about 130 kg, which is the figure to use for a steel take-off or when checking a lift.

The elastic section modulus about the major axis, Wel,y, is 14 cm³. Angles are tabulated about their principal (u-u and v-v) axes rather than a plastic major-axis modulus, so the elastic value is the one to design from unless you are working from the principal-axis properties directly.

The second moment of area about the major axis, Iy, is 66.8 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

iy is 2.2 cm about the major axis and iz is 1.9 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 1.9 cm a 0.2 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

Related UA Back to Back sizes

UA 80×60×7 BtBUA 80×40×8 BtBUA 80×40×6 BtBUA 75×50×8 BtBUA 75×50×6 BtBUA 65×50×5 BtBUA 60×40×6 BtBUA 60×40×5 BtB

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)