24F-1.8E (SP/SP) - Design Values

24F-1.8E (SP/SP) is a glued-laminated timber grade with reference design values to NDS 2018 Supplement Table 5A. Its reference bending value Fb is 2,400 psi, compression parallel Fc is 1,650 psi, and modulus of elasticity E is 1,800,000 psi (NDS). Values are shown before adjustment factors; apply the relevant NDS C-factors or EC5 k_mod and γ_M for your load case.

Fb (bending)
2,400 psi
Fc (compression)
1,650 psi
E (modulus)
1.8M psi
Reference design values (NDS 2018)
FbBending2,400 psi
FtTension parallel1,150 psi
FvShear parallel300 psi
Fc⊥Compression perpendicular740 psi
FcCompression parallel1,650 psi
EModulus of elasticity1,800,000 psi
EminModulus for stability950,000 psi

Southern Pine combination; higher shear (Fv = 300 psi) than the Douglas Fir combinations.

Source: NDS 2018 Supplement Table 5A. Reference values are shown before adjustment factors (NDS C-factors / EC5 k_mod, γ_M) - apply these per your load case in design.