EN 10080 / Eurocode reinforcement - Bar Sizes
European ribbed reinforcing bar (EN 10080), grade B500A/B/C, used with Eurocode 2 (EN 1992-1-1). Diameters 6-40 mm.
Grades: B500A / B500B / B500C - characteristic yield f_yk = 500 MPa (ductility class differs: A/B/C).
| Bar | Diameter | Area As | Mass |
|---|---|---|---|
| 6 mm | 6 mm | 28.3 mm² | 0.222 kg/m |
| 8 mm | 8 mm | 50.3 mm² | 0.395 kg/m |
| 10 mm | 10 mm | 78.5 mm² | 0.617 kg/m |
| 12 mm | 12 mm | 113.1 mm² | 0.888 kg/m |
| 14 mm | 14 mm | 153.9 mm² | 1.208 kg/m |
| 16 mm | 16 mm | 201.1 mm² | 1.578 kg/m |
| 20 mm | 20 mm | 314.2 mm² | 2.466 kg/m |
| 25 mm | 25 mm | 490.9 mm² | 3.853 kg/m |
| 28 mm | 28 mm | 615.8 mm² | 4.834 kg/m |
| 32 mm | 32 mm | 804.2 mm² | 6.313 kg/m |
| 40 mm | 40 mm | 1256.6 mm² | 9.864 kg/m |