CivilAxisCivilAxis
☕ Support🌐 Community

20 mm Reinforcing Bar - EN / Eurocode

20 mm is a EN / Eurocode reinforcing bar to EN 10080 / EN 1992-1-1. Its nominal diameter is 20 mm, giving a cross-section area As of 314.2 mm² and a mass of 2.466 kg/m. It is supplied in grade B500A / B500B / B500C with characteristic yield f_yk = 500 MPa. The tables below give the total steel area for 1-10 bars and the area per metre of width at common bar spacings.

Area As
314.2 mm²
Diameter
20 mm
Mass
2.466 kg/m
f_yk
500 MPa
Bar properties
dNominal diameter20 mm
AsCross-section area314.2 mm²
mMass per metre2.466 kg/m
uNominal perimeter62.8 mm
f_ykCharacteristic yield500 MPa
Total area for n bars (As = n × 314.2 mm²)
Bars12345678910
As (mm²)3146289431,2571,5711,8852,1992,5142,8283,142
Area per metre at spacing (As/m = 1000/s × 314.2 mm²)
s (mm)75100125150175200250300
As/m (mm²/m)4,1893,1422,5142,0951,7951,5711,2571,047

Source: EN 10080 / EN 1992-1-1. Area = π/4 × d² for metric bars; ASTM areas are the standard's tabulated nominal values. Grades available: B500A, B500B, B500C.

Understanding these values

20 mm is a ribbed reinforcing bar to EN 10080 / EN 1992-1-1, the Eurocode reinforcement standard. It is produced in B500A / B500B / B500C, where the 500 is the characteristic yield f_yk in MPa and the trailing letter is the ductility class rather than a strength difference. Its nominal diameter is 20 mm, which gives a cross-sectional area As of 314.2 mm² from pi/4 times the diameter squared, and a mass of 2.466 kg/m - so a 12 m length weighs about 29.6 kg. The nominal perimeter, used in bond and anchorage calculations, is 62.8 mm.

It is supplied in B500A, B500B, B500C, all sharing f_yk = 500 MPa and differing in ductility class: the trailing A, B or C sets the elongation and hardening requirements, with C required where plastic rotation capacity matters. The grade affects the strength you design to, not the geometry: the area of 314.2 mm² and the mass of 2.466 kg/m are the same whichever grade of EN / Eurocode bar is specified.

For slabs and walls the number you need is area per metre width, which is the bar area times 1,000 divided by the spacing. At 150 mm centres 20 mm gives 2095 mm²/m, at 200 mm centres 1571 mm²/m, and at 250 mm centres 1257 mm²/m. Compare those against the As,req from your slab design, take the first arrangement that satisfies it, and then check the spacing against the maximum bar spacing EN 1992-1-1 allows for crack control - a larger bar at wider centres can meet the area and still fail that limit.

If you are working across standards, the nearest equivalents by area are TCVN (Vietnam) 20 mm at 314.2 mm² (effectively identical), ASTM (US) #6 (No. 6) at 284 mm² (10% smaller), BS (UK) H20 (20 mm) at 314.2 mm² (effectively identical). Matching on area is the right first step, but it is not a code-sanctioned substitution: changing standard means re-checking anchorage length, lap length, bond and crack width, because those depend on bar surface geometry and the concrete, not on area alone.

Common questions

A 20 mm bar has a nominal cross-sectional area of 314.2 mm² to EN 10080 / EN 1992-1-1. This follows from pi/4 times the 20 mm diameter squared.

20 mm to EN 10080 / EN 1992-1-1 weighs 2.466 kg per metre. That comes from its 314.2 mm² area multiplied by the density of steel, 7,850 kg/m³. A 12 m length therefore weighs about 29.6 kg, which is the figure to use when estimating a bar schedule.

It is supplied in B500A, B500B, B500C, with a characteristic yield f_yk of 500 MPa for the primary grade to EN 10080 / EN 1992-1-1. The grade changes the design strength and the ductility class, not the geometry - area stays 314.2 mm² and mass stays 2.466 kg/m across all of them.

1571 mm² per metre width. The calculation is the bar area times 1,000 divided by the spacing: 314.2 x 1000 / 200 = 1571 mm²/m. At 150 mm centres the same bar gives 2095 mm²/m and at 250 mm centres 1257 mm²/m. Check the spacing against the crack-control limit in EN 1992-1-1 as well as the area.

By area, the closest is 20 mm at 314.2 mm² against 314.2 mm² here - effectively identical. Treat that as a starting point rather than an equivalence: a change of standard requires re-checking anchorage and lap lengths, bond and crack width, which depend on rib geometry and concrete grade as well as on area.

Other EN / Eurocode bar sizes

6 mm8 mm10 mm12 mm14 mm16 mm25 mm28 mm32 mm40 mm
Rate this
No ratings yet
Sign in to join the discussion.
Loading…