C 8X18.75 is an C section from the American AISC Shapes Database; PFC 200×75 is the closest equivalent in the European (Continental) range. They are close to interchangeable in bending: 227.78 cm³ against 227 cm³ of plastic modulus, a difference of 0.3%. PFC 200×75 is the lighter of the two at 23.4 kg/m against 27.9 kg/m, a saving of 19.2% on steel weight. Both are about 202 mm deep, so either fits the same construction zone.

Section properties side by side. Bold marks the more favourable value where one is.
PropertyC 8X18.75
C
PFC 200×75
PFC
Difference
Mass27.9 kg/m23.4 kg/m+19.2%
Depth203.2 mm200 mm+1.6%
Width64.3 mm75 mm-14.3%
Web thickness12.4 mm6 mm+106.7%
Flange thickness9.9 mm12.5 mm-20.8%
Area35.5 cm²29.9 cm²+18.7%
Second moment, major (Iy)1,827 cm⁴1,963 cm⁴-6.9%
Plastic modulus, major (Wpl,y)227.78 cm³227 cm³+0.3%
Elastic modulus, major (Wel,y)180.26 cm³196 cm³-8.0%
Second moment, minor (Iz)82 cm⁴170 cm⁴-51.8%
Plastic modulus, minor (Wpl,z)35.56 cm³60.6 cm³-41.3%
Radius of gyration, minor (iz)1.52 cm2.39 cm-36.4%
Torsion constant (It)18.06 cm⁴11.1 cm⁴+62.7%

C 8X18.75 to AISC Shapes Database v16.0; PFC 200×75 to Continental Steel. Difference is expressed relative to PFC 200×75.

How to choose between them

On stiffness, PFC 200×75 has the larger second moment of area: 1,963 cm⁴ against 1,827 cm⁴, a difference of 6.9%. This matters more often than the strength comparison, because on normal floor spans deflection rather than bending capacity sets the beam size - so if the two are close on modulus but apart on inertia, the stiffer one is usually the better answer even when it is not the stronger one.

Measured as bending capacity per kilogram of steel, PFC 200×75 is the more efficient section: 9.7 against 8.2 cm³ per kg/m, 15.8% better. Over a floor of repeated beams that difference is real tonnage, though it is often outweighed by whichever section the fabricator can actually source.

The two diverge much more about the minor axis: PFC 200×75 has 60.6 cm³ of minor-axis plastic modulus against 35.56 cm³, 41.3% more. If the member sees any minor-axis bending, or if it is unrestrained over a long length and lateral-torsional buckling governs, that gap decides the comparison even though the major-axis numbers looked equivalent.

These come from different catalogues, so treat the swap as a design change rather than a like-for-like substitution. C sections are specified to AISC Shapes Database v16.0 and PFC to Continental Steel; the steel grades, tolerances and available lengths differ, connection details and bolt gauges are set out differently, and the two are rarely both stocked in the same market. Check availability before changing a section on a drawing to save 19.2% weight.

In short, C 8X18.75 is the stronger section and PFC 200×75 is the lighter one; where those are the same section, it is the clear choice, and where they are not, decide on whether your design is governed by capacity or by tonnage.

Common questions

They are effectively equal in bending. C 8X18.75 has a plastic modulus of 227.78 cm³ and PFC 200×75 has 227 cm³, a difference of only 0.3% - within the margin that section choice normally turns on. Compare stiffness and availability instead.

PFC 200×75 at 23.4 kg/m, against 27.9 kg/m for the other - a saving of 19.2%. Over a repeated floor beam that is a real cost difference, but check it against the deflection case before taking it.

Structurally it is the closest equivalent we hold: PFC 200×75 gives 227 cm³ of plastic modulus and 1,963 cm⁴ of inertia against 227.78 cm³ and 1,827 cm⁴. But they are from different catalogues (AISC Shapes Database v16.0 and Continental Steel), so this is a design change, not a drop-in swap: re-check deflection, connection detailing and local availability.

PFC 200×75, with a second moment of area of 1,963 cm⁴ against 1,827 cm⁴ (6.9% more). Deflection under a uniform load goes as 5wL⁴/384EI, so it is inversely proportional to I - on a span where the deflection limit governs rather than strength, this is the number that decides the section.

Related comparisons

PFC 200×75×23 vs PFC 200×75PFC 200×75×23 vs C 8X18.75
Rate this
No ratings yet