W 12X22 vs H-300x150x5.5x8

W 12X22 is an W section from the American AISC Shapes Database; H-300x150x5.5x8 is the closest equivalent in the European (Continental) range. They are close to interchangeable in bending: 480.14 cm³ against 475 cm³ of plastic modulus, a difference of 1.1%. H-300x150x5.5x8 is the lighter of the two at 32 kg/m against 32.7 kg/m, a saving of 2.2% on steel weight. W 12X22 is deeper, 312.4 mm against 298 mm, which matters where the floor zone is tight.

Section properties side by side. Bold marks the more favourable value where one is.
PropertyW 12X22
W
H-300x150x5.5x8
MB & MC
Difference
Mass32.7 kg/m32 kg/m+2.2%
Depth312.4 mm298 mm+4.8%
Width102.4 mm149 mm-31.3%
Web thickness6.6 mm5.5 mm+20.0%
Flange thickness10.8 mm8 mm+35.0%
Area41.8 cm²40.8 cm²+2.5%
Second moment, major (Iy)6,493 cm⁴6,318 cm⁴+2.8%
Plastic modulus, major (Wpl,y)480.14 cm³475 cm³+1.1%
Elastic modulus, major (Wel,y)416.23 cm³424 cm³-1.8%
Second moment, minor (Iz)194 cm⁴442 cm⁴-56.1%
Plastic modulus, minor (Wpl,z)59.977 cm³91.8 cm³-34.7%
Radius of gyration, minor (iz)2.15 cm3.29 cm-34.7%
Torsion constant (It)12.2 cm⁴8.65 cm⁴+41.0%

W 12X22 to AISC Shapes Database v16.0; H-300x150x5.5x8 to Continental Steel. Difference is expressed relative to H-300x150x5.5x8.

How to choose between them

On stiffness, W 12X22 has the larger second moment of area: 6,493 cm⁴ against 6,318 cm⁴, a difference of 2.8%. This matters more often than the strength comparison, because on normal floor spans deflection rather than bending capacity sets the beam size - so if the two are close on modulus but apart on inertia, the stiffer one is usually the better answer even when it is not the stronger one.

Measured as bending capacity per kilogram, the two are equally efficient (14.7 against 14.8 cm³ per kg/m), so on a pure steel-tonnage basis there is nothing to choose between them. The decision comes down to availability, connection detailing and what the rest of the frame uses.

The two diverge much more about the minor axis: H-300x150x5.5x8 has 91.8 cm³ of minor-axis plastic modulus against 59.977 cm³, 34.7% more. If the member sees any minor-axis bending, or if it is unrestrained over a long length and lateral-torsional buckling governs, that gap decides the comparison even though the major-axis numbers looked equivalent.

These come from different catalogues, so treat the swap as a design change rather than a like-for-like substitution. W sections are specified to AISC Shapes Database v16.0 and MB & MC to Continental Steel; the steel grades, tolerances and available lengths differ, connection details and bolt gauges are set out differently, and the two are rarely both stocked in the same market. Check availability before changing a section on a drawing to save 2.2% weight.

In short, W 12X22 is the stronger section and H-300x150x5.5x8 is the lighter one; where those are the same section, it is the clear choice, and where they are not, decide on whether your design is governed by capacity or by tonnage.

Common questions

They are effectively equal in bending. W 12X22 has a plastic modulus of 480.14 cm³ and H-300x150x5.5x8 has 475 cm³, a difference of only 1.1% - within the margin that section choice normally turns on. Compare stiffness and availability instead.

H-300x150x5.5x8 at 32 kg/m, against 32.7 kg/m for the other - a saving of 2.2%. Over a repeated floor beam that is a real cost difference, but check it against the deflection case before taking it.

Structurally it is the closest equivalent we hold: H-300x150x5.5x8 gives 475 cm³ of plastic modulus and 6,318 cm⁴ of inertia against 480.14 cm³ and 6,493 cm⁴. But they are from different catalogues (AISC Shapes Database v16.0 and Continental Steel), so this is a design change, not a drop-in swap: re-check deflection, connection detailing and local availability.

W 12X22, with a second moment of area of 6,493 cm⁴ against 6,318 cm⁴ (2.8% more). Deflection under a uniform load goes as 5wL⁴/384EI, so it is inversely proportional to I - on a span where the deflection limit governs rather than strength, this is the number that decides the section.

Related comparisons

UB 305×102×33 vs W 12X22UB 305×102×33 vs H-300x150x5.5x8