CivilAxisCivilAxis
☕ Support🌐 Community

W 12X58 vs HP 12X63

W 12X58 is an W section from the American AISC Shapes Database; HP 12X63 is the closest equivalent in the American AISC Shapes Database. HP 12X63 carries more bending: 1447 cm³ of plastic modulus against 1415.8 cm³, 2.2% more. W 12X58 is the lighter of the two at 86.3 kg/m against 93.8 kg/m, a saving of 8.0% on steel weight. W 12X58 is deeper, 309.9 mm against 302.3 mm, which matters where the floor zone is tight.

Section properties side by side. Bold marks the more favourable value where one is.
PropertyW 12X58
W
HP 12X63
HP
Difference
Mass86.3 kg/m93.8 kg/m-8.0%
Depth309.9 mm302.3 mm+2.5%
Width254 mm307.3 mm-17.3%
Web thickness9.1 mm13.1 mm-30.5%
Flange thickness16.3 mm13.1 mm+24.4%
Area109.7 cm²118.7 cm²-7.6%
Second moment, major (Iy)19,771 cm⁴19,646 cm⁴+0.6%
Plastic modulus, major (Wpl,y)1,415.8 cm³1,447 cm³-2.2%
Elastic modulus, major (Wel,y)1,278.2 cm³1,296.2 cm³-1.4%
Second moment, minor (Iz)4,454 cm⁴6,368 cm⁴-30.1%
Plastic modulus, minor (Wpl,z)532.58 cm³634.18 cm³-16.0%
Radius of gyration, minor (iz)6.38 cm7.32 cm-12.8%
Torsion constant (It)87.41 cm⁴76.17 cm⁴+14.8%

W 12X58 to AISC Shapes Database v16.0; HP 12X63 to AISC Shapes Database v16.0. Difference is expressed relative to HP 12X63.

How to choose between them

On stiffness, W 12X58 has the larger second moment of area: 19,771 cm⁴ against 19,646 cm⁴, a difference of 0.6%. This matters more often than the strength comparison, because on normal floor spans deflection rather than bending capacity sets the beam size - so if the two are close on modulus but apart on inertia, the stiffer one is usually the better answer even when it is not the stronger one.

Measured as bending capacity per kilogram of steel, W 12X58 is the more efficient section: 16.4 against 15.4 cm³ per kg/m, 6.3% better. Over a floor of repeated beams that difference is real tonnage, though it is often outweighed by whichever section the fabricator can actually source.

The two diverge much more about the minor axis: HP 12X63 has 634.18 cm³ of minor-axis plastic modulus against 532.58 cm³, 16.0% more. If the member sees any minor-axis bending, or if it is unrestrained over a long length and lateral-torsional buckling governs, that gap decides the comparison even though the major-axis numbers looked equivalent.

In short, HP 12X63 is the stronger section and W 12X58 is the lighter one; where those are the same section, it is the clear choice, and where they are not, decide on whether your design is governed by capacity or by tonnage.

Common questions

HP 12X63 is the stronger of the two in bending, with a plastic modulus of 1447 cm³ against 1415.8 cm³ - 2.2% more. At the same steel grade that translates directly into moment capacity, since M_pl,Rd = W_pl x f_y / gamma_M0.

W 12X58 at 86.3 kg/m, against 93.8 kg/m for the other - a saving of 8.0%. Over a repeated floor beam that is a real cost difference, but check it against the deflection case before taking it.

Structurally it is the closest equivalent we hold: HP 12X63 gives 1447 cm³ of plastic modulus and 19,646 cm⁴ of inertia against 1415.8 cm³ and 19,771 cm⁴. Re-check deflection and the connection details before swapping, since the flange and web thicknesses differ.

W 12X58, with a second moment of area of 19,771 cm⁴ against 19,646 cm⁴ (0.6% more). Deflection under a uniform load goes as 5wL⁴/384EI, so it is inversely proportional to I - on a span where the deflection limit governs rather than strength, this is the number that decides the section.

Related comparisons

W 12X58 vs H-300x300x9x14
Rate this
No ratings yet
Sign in to join the discussion.
Loading…