CivilAxisCivilAxis
☕ Support🌐 Community

W 24X176 vs HE 700 B

W 24X176 is an W section from the American AISC Shapes Database; HE 700 B is the closest equivalent in the European (Continental) range. They are close to interchangeable in bending: 8373.8 cm³ against 8330 cm³ of plastic modulus, a difference of 0.5%. HE 700 B is the lighter of the two at 241 kg/m against 261.9 kg/m, a saving of 8.7% on steel weight. HE 700 B is deeper, 700 mm against 640.1 mm, which matters where the floor zone is tight.

Section properties side by side. Bold marks the more favourable value where one is.
PropertyW 24X176
W
HE 700 B
HE
Difference
Mass261.9 kg/m241 kg/m+8.7%
Depth640.1 mm700 mm-8.6%
Width327.7 mm300 mm+9.2%
Web thickness19 mm17 mm+11.8%
Flange thickness34 mm32 mm+6.3%
Area333.5 cm²306 cm²+9.0%
Second moment, major (Iy)236,419 cm⁴257,000 cm⁴-8.0%
Plastic modulus, major (Wpl,y)8,373.8 cm³8,330 cm³+0.5%
Elastic modulus, major (Wel,y)7,374.2 cm³7,340 cm³+0.5%
Second moment, minor (Iz)19,937 cm⁴14,400 cm⁴+38.5%
Plastic modulus, minor (Wpl,z)1,884.5 cm³1,500 cm³+25.6%
Radius of gyration, minor (iz)7.72 cm6.87 cm+12.4%
Torsion constant (It)994.8 cm⁴839 cm⁴+18.6%

W 24X176 to AISC Shapes Database v16.0; HE 700 B to EN 10365 · Continental Steel. Difference is expressed relative to HE 700 B.

How to choose between them

On stiffness, HE 700 B has the larger second moment of area: 257,000 cm⁴ against 236,419 cm⁴, a difference of 8.0%. This matters more often than the strength comparison, because on normal floor spans deflection rather than bending capacity sets the beam size - so if the two are close on modulus but apart on inertia, the stiffer one is usually the better answer even when it is not the stronger one.

Measured as bending capacity per kilogram of steel, HE 700 B is the more efficient section: 34.6 against 32.0 cm³ per kg/m, 7.5% better. Over a floor of repeated beams that difference is real tonnage, though it is often outweighed by whichever section the fabricator can actually source.

The two diverge much more about the minor axis: W 24X176 has 1884.5 cm³ of minor-axis plastic modulus against 1500 cm³, 25.6% more. If the member sees any minor-axis bending, or if it is unrestrained over a long length and lateral-torsional buckling governs, that gap decides the comparison even though the major-axis numbers looked equivalent.

These come from different catalogues, so treat the swap as a design change rather than a like-for-like substitution. W sections are specified to AISC Shapes Database v16.0 and HE to EN 10365 · Continental Steel; the steel grades, tolerances and available lengths differ, connection details and bolt gauges are set out differently, and the two are rarely both stocked in the same market. Check availability before changing a section on a drawing to save 8.7% weight.

In short, W 24X176 is the stronger section and HE 700 B is the lighter one; where those are the same section, it is the clear choice, and where they are not, decide on whether your design is governed by capacity or by tonnage.

Common questions

They are effectively equal in bending. W 24X176 has a plastic modulus of 8373.8 cm³ and HE 700 B has 8330 cm³, a difference of only 0.5% - within the margin that section choice normally turns on. Compare stiffness and availability instead.

HE 700 B at 241 kg/m, against 261.9 kg/m for the other - a saving of 8.7%. Over a repeated floor beam that is a real cost difference, but check it against the deflection case before taking it.

Structurally it is the closest equivalent we hold: HE 700 B gives 8330 cm³ of plastic modulus and 257,000 cm⁴ of inertia against 8373.8 cm³ and 236,419 cm⁴. But they are from different catalogues (AISC Shapes Database v16.0 and EN 10365 · Continental Steel), so this is a design change, not a drop-in swap: re-check deflection, connection detailing and local availability.

HE 700 B, with a second moment of area of 257,000 cm⁴ against 236,419 cm⁴ (8.0% more). Deflection under a uniform load goes as 5wL⁴/384EI, so it is inversely proportional to I - on a span where the deflection limit governs rather than strength, this is the number that decides the section.