HE 200 A vs H-200x200x6.5x10

HE 200 A is an HE section from the European (Continental) range; H-200x200x6.5x10 is the closest equivalent in the European (Continental) range. They are close to interchangeable in bending: 430 cm³ against 433 cm³ of plastic modulus, a difference of 0.7%. H-200x200x6.5x10 is the lighter of the two at 41.4 kg/m against 42.3 kg/m, a saving of 2.2% on steel weight. H-200x200x6.5x10 is deeper, 196 mm against 190 mm, which matters where the floor zone is tight.

Section properties side by side. Bold marks the more favourable value where one is.
PropertyHE 200 A
HE
H-200x200x6.5x10
MB & MC
Difference
Mass42.3 kg/m41.4 kg/m+2.2%
Depth190 mm196 mm-3.1%
Width200 mm199 mm+0.5%
Web thickness6.5 mm6.5 mmsame
Flange thickness10 mm10 mmsame
Area53.8 cm²52.7 cm²+2.1%
Second moment, major (Iy)3,690 cm⁴3,846 cm⁴-4.1%
Plastic modulus, major (Wpl,y)430 cm³433 cm³-0.7%
Elastic modulus, major (Wel,y)389 cm³392 cm³-0.8%
Second moment, minor (Iz)1,340 cm⁴1,315 cm⁴+1.9%
Plastic modulus, minor (Wpl,z)204 cm³201 cm³+1.5%
Radius of gyration, minor (iz)4.98 cm5 cm-0.4%
Torsion constant (It)21 cm⁴17.6 cm⁴+19.3%

HE 200 A to EN 10365 · Continental Steel; H-200x200x6.5x10 to Continental Steel. Difference is expressed relative to H-200x200x6.5x10.

How to choose between them

On stiffness, H-200x200x6.5x10 has the larger second moment of area: 3,846 cm⁴ against 3,690 cm⁴, a difference of 4.1%. This matters more often than the strength comparison, because on normal floor spans deflection rather than bending capacity sets the beam size - so if the two are close on modulus but apart on inertia, the stiffer one is usually the better answer even when it is not the stronger one.

Measured as bending capacity per kilogram of steel, H-200x200x6.5x10 is the more efficient section: 10.5 against 10.2 cm³ per kg/m, 2.8% better. Over a floor of repeated beams that difference is real tonnage, though it is often outweighed by whichever section the fabricator can actually source.

In short, H-200x200x6.5x10 is the stronger section and H-200x200x6.5x10 is the lighter one; where those are the same section, it is the clear choice, and where they are not, decide on whether your design is governed by capacity or by tonnage.

Common questions

They are effectively equal in bending. HE 200 A has a plastic modulus of 430 cm³ and H-200x200x6.5x10 has 433 cm³, a difference of only 0.7% - within the margin that section choice normally turns on. Compare stiffness and availability instead.

H-200x200x6.5x10 at 41.4 kg/m, against 42.3 kg/m for the other - a saving of 2.2%. Over a repeated floor beam that is a real cost difference, but check it against the deflection case before taking it.

Structurally it is the closest equivalent we hold: H-200x200x6.5x10 gives 433 cm³ of plastic modulus and 3,846 cm⁴ of inertia against 430 cm³ and 3,690 cm⁴. Re-check deflection and the connection details before swapping, since the flange and web thicknesses differ.

H-200x200x6.5x10, with a second moment of area of 3,846 cm⁴ against 3,690 cm⁴ (4.1% more). Deflection under a uniform load goes as 5wL⁴/384EI, so it is inversely proportional to I - on a span where the deflection limit governs rather than strength, this is the number that decides the section.