PFC 260×75×28 vs C 10X20

PFC 260×75×28 is an PFC section from the UK Blue Book (SCI P363); C 10X20 is the closest equivalent in the American AISC Shapes Database. PFC 260×75×28 carries more bending: 328 cm³ of plastic modulus against 317.91 cm³, 3.2% more. PFC 260×75×28 is the lighter of the two at 27.6 kg/m against 29.8 kg/m, a saving of 7.4% on steel weight. PFC 260×75×28 is deeper, 260 mm against 254 mm, which matters where the floor zone is tight.

Section properties side by side. Bold marks the more favourable value where one is.
PropertyPFC 260×75×28
PFC
C 10X20
C
Difference
Mass27.6 kg/m29.8 kg/m-7.4%
Depth260 mm254 mm+2.4%
Width75 mm69.6 mm+7.8%
Web thickness7 mm9.6 mm-27.1%
Flange thickness12 mm11.1 mm+8.1%
Area35.1 cm²37.9 cm²-7.4%
Second moment, major (Iy)3,620 cm⁴3,284 cm⁴+10.2%
Plastic modulus, major (Wpl,y)328 cm³317.91 cm³+3.2%
Elastic modulus, major (Wel,y)278 cm³258.92 cm³+7.4%
Second moment, minor (Iz)185 cm⁴116.5 cm⁴+58.8%
Plastic modulus, minor (Wpl,z)62 cm³44.245 cm³+40.1%
Radius of gyration, minor (iz)2.3 cm1.75 cm+31.4%
Torsion constant (It)11.7 cm⁴15.32 cm⁴-23.6%

PFC 260×75×28 to BS EN 1993-1-1:2005 / BS 4-1:2005; C 10X20 to AISC Shapes Database v16.0. Difference is expressed relative to C 10X20.

How to choose between them

On stiffness, PFC 260×75×28 has the larger second moment of area: 3,620 cm⁴ against 3,284 cm⁴, a difference of 10.2%. This matters more often than the strength comparison, because on normal floor spans deflection rather than bending capacity sets the beam size - so if the two are close on modulus but apart on inertia, the stiffer one is usually the better answer even when it is not the stronger one.

Measured as bending capacity per kilogram of steel, PFC 260×75×28 is the more efficient section: 11.9 against 10.7 cm³ per kg/m, 11.4% better. Over a floor of repeated beams that difference is real tonnage, though it is often outweighed by whichever section the fabricator can actually source.

The two diverge much more about the minor axis: PFC 260×75×28 has 62 cm³ of minor-axis plastic modulus against 44.245 cm³, 40.1% more. If the member sees any minor-axis bending, or if it is unrestrained over a long length and lateral-torsional buckling governs, that gap decides the comparison even though the major-axis numbers looked equivalent.

These come from different catalogues, so treat the swap as a design change rather than a like-for-like substitution. PFC sections are specified to BS EN 1993-1-1:2005 / BS 4-1:2005 and C to AISC Shapes Database v16.0; the steel grades, tolerances and available lengths differ, connection details and bolt gauges are set out differently, and the two are rarely both stocked in the same market. Check availability before changing a section on a drawing to save 7.4% weight.

In short, PFC 260×75×28 is the stronger section and PFC 260×75×28 is the lighter one; where those are the same section, it is the clear choice, and where they are not, decide on whether your design is governed by capacity or by tonnage.

Common questions

PFC 260×75×28 is the stronger of the two in bending, with a plastic modulus of 328 cm³ against 317.91 cm³ - 3.2% more. At the same steel grade that translates directly into moment capacity, since M_pl,Rd = W_pl x f_y / gamma_M0.

PFC 260×75×28 at 27.6 kg/m, against 29.8 kg/m for the other - a saving of 7.4%. Over a repeated floor beam that is a real cost difference, but check it against the deflection case before taking it.

Structurally it is the closest equivalent we hold: C 10X20 gives 317.91 cm³ of plastic modulus and 3,284 cm⁴ of inertia against 328 cm³ and 3,620 cm⁴. But they are from different catalogues (BS EN 1993-1-1:2005 / BS 4-1:2005 and AISC Shapes Database v16.0), so this is a design change, not a drop-in swap: re-check deflection, connection detailing and local availability.

PFC 260×75×28, with a second moment of area of 3,620 cm⁴ against 3,284 cm⁴ (10.2% more). Deflection under a uniform load goes as 5wL⁴/384EI, so it is inversely proportional to I - on a span where the deflection limit governs rather than strength, this is the number that decides the section.