RHS 100×60×4 vs CF RHS 100×60×4

RHS 100×60×4 is an RHS Hot-finished section from the UK Blue Book (SCI P363); CF RHS 100×60×4 is the closest equivalent in the UK Blue Book (SCI P363). RHS 100×60×4 carries more bending: 39.1 cm³ of plastic modulus against 37.9 cm³, 3.2% more. CF RHS 100×60×4 is the lighter of the two at 9.22 kg/m against 9.41 kg/m, a saving of 2.1% on steel weight. Both are about 100 mm deep, so either fits the same construction zone.

Section properties side by side. Bold marks the more favourable value where one is.
PropertyRHS 100×60×4
RHS Hot-finished
CF RHS 100×60×4
RHS Cold-formed
Difference
Mass9.4 kg/m9.2 kg/m+2.1%
Depth100 mm100 mmsame
Width60 mm60 mmsame
Web thickness0 mm0 mmsame
Flange thickness0 mm0 mmsame
Area12 cm²11.7 cm²+2.6%
Second moment, major (Iy)158 cm⁴153 cm⁴+3.3%
Plastic modulus, major (Wpl,y)39.1 cm³37.9 cm³+3.2%
Elastic modulus, major (Wel,y)31.6 cm³30.5 cm³+3.6%
Second moment, minor (Iz)70.5 cm⁴68.7 cm⁴+2.6%
Plastic modulus, minor (Wpl,z)27.3 cm³26.6 cm³+2.6%
Radius of gyration, minor (iz)2.43 cm2.42 cm+0.4%
Torsion constant (It)156 cm⁴156 cm⁴same

RHS 100×60×4 to BS EN 10210-2:2006; CF RHS 100×60×4 to BS EN 10219-2:2006. Difference is expressed relative to CF RHS 100×60×4.

How to choose between them

On stiffness, RHS 100×60×4 has the larger second moment of area: 158 cm⁴ against 153 cm⁴, a difference of 3.3%. This matters more often than the strength comparison, because on normal floor spans deflection rather than bending capacity sets the beam size - so if the two are close on modulus but apart on inertia, the stiffer one is usually the better answer even when it is not the stronger one.

Measured as bending capacity per kilogram, the two are equally efficient (4.2 against 4.1 cm³ per kg/m), so on a pure steel-tonnage basis there is nothing to choose between them. The decision comes down to availability, connection detailing and what the rest of the frame uses.

In short, RHS 100×60×4 is the stronger section and CF RHS 100×60×4 is the lighter one; where those are the same section, it is the clear choice, and where they are not, decide on whether your design is governed by capacity or by tonnage.

Common questions

RHS 100×60×4 is the stronger of the two in bending, with a plastic modulus of 39.1 cm³ against 37.9 cm³ - 3.2% more. At the same steel grade that translates directly into moment capacity, since M_pl,Rd = W_pl x f_y / gamma_M0.

CF RHS 100×60×4 at 9.22 kg/m, against 9.41 kg/m for the other - a saving of 2.1%. Over a repeated floor beam that is a real cost difference, but check it against the deflection case before taking it.

Structurally it is the closest equivalent we hold: CF RHS 100×60×4 gives 37.9 cm³ of plastic modulus and 153 cm⁴ of inertia against 39.1 cm³ and 158 cm⁴. Re-check deflection and the connection details before swapping, since the flange and web thicknesses differ.

RHS 100×60×4, with a second moment of area of 158 cm⁴ against 153 cm⁴ (3.3% more). Deflection under a uniform load goes as 5wL⁴/384EI, so it is inversely proportional to I - on a span where the deflection limit governs rather than strength, this is the number that decides the section.