RHS 180×60×8 vs CF RHS 180×100×6

RHS 180×60×8 is an RHS Hot-finished section from the UK Blue Book (SCI P363); CF RHS 180×100×6 is the closest equivalent in the UK Blue Book (SCI P363). They are close to interchangeable in bending: 184 cm³ against 181 cm³ of plastic modulus, a difference of 1.7%. CF RHS 180×100×6 is the lighter of the two at 24.5 kg/m against 27.6 kg/m, a saving of 12.7% on steel weight. Both are about 180 mm deep, so either fits the same construction zone.

Section properties side by side. Bold marks the more favourable value where one is.
PropertyRHS 180×60×8
RHS Hot-finished
CF RHS 180×100×6
RHS Cold-formed
Difference
Mass27.6 kg/m24.5 kg/m+12.7%
Depth180 mm180 mmsame
Width60 mm100 mm-40.0%
Web thickness0 mm0 mmsame
Flange thickness0 mm0 mmsame
Area35.2 cm²31.2 cm²+12.8%
Second moment, major (Iy)1,240 cm⁴1,310 cm⁴-5.3%
Plastic modulus, major (Wpl,y)184 cm³181 cm³+1.7%
Elastic modulus, major (Wel,y)138 cm³146 cm³-5.5%
Second moment, minor (Iz)201 cm⁴524 cm⁴-61.6%
Plastic modulus, minor (Wpl,z)80.4 cm³120 cm³-33.0%
Radius of gyration, minor (iz)2.39 cm4.1 cm-41.7%
Torsion constant (It)590 cm⁴1,230 cm⁴-52.0%

RHS 180×60×8 to BS EN 10210-2:2006; CF RHS 180×100×6 to BS EN 10219-2:2006. Difference is expressed relative to CF RHS 180×100×6.

How to choose between them

On stiffness, CF RHS 180×100×6 has the larger second moment of area: 1,310 cm⁴ against 1,240 cm⁴, a difference of 5.3%. This matters more often than the strength comparison, because on normal floor spans deflection rather than bending capacity sets the beam size - so if the two are close on modulus but apart on inertia, the stiffer one is usually the better answer even when it is not the stronger one.

Measured as bending capacity per kilogram of steel, CF RHS 180×100×6 is the more efficient section: 7.4 against 6.7 cm³ per kg/m, 9.8% better. Over a floor of repeated beams that difference is real tonnage, though it is often outweighed by whichever section the fabricator can actually source.

The two diverge much more about the minor axis: CF RHS 180×100×6 has 120 cm³ of minor-axis plastic modulus against 80.4 cm³, 33.0% more. If the member sees any minor-axis bending, or if it is unrestrained over a long length and lateral-torsional buckling governs, that gap decides the comparison even though the major-axis numbers looked equivalent.

In short, RHS 180×60×8 is the stronger section and CF RHS 180×100×6 is the lighter one; where those are the same section, it is the clear choice, and where they are not, decide on whether your design is governed by capacity or by tonnage.

Common questions

They are effectively equal in bending. RHS 180×60×8 has a plastic modulus of 184 cm³ and CF RHS 180×100×6 has 181 cm³, a difference of only 1.7% - within the margin that section choice normally turns on. Compare stiffness and availability instead.

CF RHS 180×100×6 at 24.5 kg/m, against 27.6 kg/m for the other - a saving of 12.7%. Over a repeated floor beam that is a real cost difference, but check it against the deflection case before taking it.

Structurally it is the closest equivalent we hold: CF RHS 180×100×6 gives 181 cm³ of plastic modulus and 1,310 cm⁴ of inertia against 184 cm³ and 1,240 cm⁴. Re-check deflection and the connection details before swapping, since the flange and web thicknesses differ.

CF RHS 180×100×6, with a second moment of area of 1,310 cm⁴ against 1,240 cm⁴ (5.3% more). Deflection under a uniform load goes as 5wL⁴/384EI, so it is inversely proportional to I - on a span where the deflection limit governs rather than strength, this is the number that decides the section.