CivilAxisCivilAxis
☕ Support🌐 Community

SHS 150×150×8.8 vs SHS 150×150×9

SHS 150×150×8.8 is an SHS Hot-finished section from the UK Blue Book (SCI P363); SHS 150×150×9 is the closest equivalent in the European (Continental) range. SHS 150×150×8.8 carries more bending: 257 cm³ of plastic modulus against 248 cm³, 3.6% more. SHS 150×150×8.8 is the lighter of the two at 38.4 kg/m against 40.52 kg/m, a saving of 5.2% on steel weight. Both are about 150 mm deep, so either fits the same construction zone.

Section properties side by side. Bold marks the more favourable value where one is.
PropertySHS 150×150×8.8
SHS Hot-finished
SHS 150×150×9
SHS Cold-formed
Difference
Mass38.4 kg/m40.5 kg/m-5.2%
Depth150 mm150 mmsame
Width150 mm150 mmsame
Web thickness0 mm0 mmsame
Flange thickness0 mm0 mmsame
Area48.9 cm²48 cm²+1.9%
Second moment, major (Iy)1,610 cm⁴1,537 cm⁴+4.7%
Plastic modulus, major (Wpl,y)257 cm³248 cm³+3.6%
Elastic modulus, major (Wel,y)214 cm³205 cm³+4.4%
Second moment, minor (Iz)1,610 cm⁴1,537 cm⁴+4.7%
Plastic modulus, minor (Wpl,z)257 cm³248 cm³+3.6%
Radius of gyration, minor (iz)5.74 cm5.66 cm+1.4%
Torsion constant (It)2,550 cm⁴2,608 cm⁴-2.2%

SHS 150×150×8.8 to BS EN 10210-2:2006; SHS 150×150×9 to EN 10219 · Continental Steel. Difference is expressed relative to SHS 150×150×9.

How to choose between them

On stiffness, SHS 150×150×8.8 has the larger second moment of area: 1,610 cm⁴ against 1,537 cm⁴, a difference of 4.7%. This matters more often than the strength comparison, because on normal floor spans deflection rather than bending capacity sets the beam size - so if the two are close on modulus but apart on inertia, the stiffer one is usually the better answer even when it is not the stronger one.

Measured as bending capacity per kilogram of steel, SHS 150×150×8.8 is the more efficient section: 6.7 against 6.1 cm³ per kg/m, 9.4% better. Over a floor of repeated beams that difference is real tonnage, though it is often outweighed by whichever section the fabricator can actually source.

These come from different catalogues, so treat the swap as a design change rather than a like-for-like substitution. SHS Hot-finished sections are specified to BS EN 10210-2:2006 and SHS Cold-formed to EN 10219 · Continental Steel; the steel grades, tolerances and available lengths differ, connection details and bolt gauges are set out differently, and the two are rarely both stocked in the same market. Check availability before changing a section on a drawing to save 5.2% weight.

In short, SHS 150×150×8.8 is the stronger section and SHS 150×150×8.8 is the lighter one; where those are the same section, it is the clear choice, and where they are not, decide on whether your design is governed by capacity or by tonnage.

Common questions

SHS 150×150×8.8 is the stronger of the two in bending, with a plastic modulus of 257 cm³ against 248 cm³ - 3.6% more. At the same steel grade that translates directly into moment capacity, since M_pl,Rd = W_pl x f_y / gamma_M0.

SHS 150×150×8.8 at 38.4 kg/m, against 40.52 kg/m for the other - a saving of 5.2%. Over a repeated floor beam that is a real cost difference, but check it against the deflection case before taking it.

Structurally it is the closest equivalent we hold: SHS 150×150×9 gives 248 cm³ of plastic modulus and 1,537 cm⁴ of inertia against 257 cm³ and 1,610 cm⁴. But they are from different catalogues (BS EN 10210-2:2006 and EN 10219 · Continental Steel), so this is a design change, not a drop-in swap: re-check deflection, connection detailing and local availability.

SHS 150×150×8.8, with a second moment of area of 1,610 cm⁴ against 1,537 cm⁴ (4.7% more). Deflection under a uniform load goes as 5wL⁴/384EI, so it is inversely proportional to I - on a span where the deflection limit governs rather than strength, this is the number that decides the section.

Related comparisons

SHS 140×140×10 vs SHS 150×150×9SHS 150×150×8 vs SHS 150×150×9SHS 150×150×8.8 vs CF SHS 150×150×10SHS 160×160×7.1 vs SHS 150×150×9
Rate this
No ratings yet
Sign in to join the discussion.