CivilAxisCivilAxis
☕ Support🌐 Community

SHS 60×60×5 vs CF SHS 60×60×5

SHS 60×60×5 is an SHS Hot-finished section from the UK Blue Book (SCI P363); CF SHS 60×60×5 is the closest equivalent in the UK Blue Book (SCI P363). SHS 60×60×5 carries more bending: 21.9 cm³ of plastic modulus against 20.9 cm³, 4.8% more. CF SHS 60×60×5 is the lighter of the two at 8.13 kg/m against 8.42 kg/m, a saving of 3.6% on steel weight. Both are about 60 mm deep, so either fits the same construction zone.

Section properties side by side. Bold marks the more favourable value where one is.
PropertySHS 60×60×5
SHS Hot-finished
CF SHS 60×60×5
SHS Cold-formed
Difference
Mass8.4 kg/m8.1 kg/m+3.6%
Depth60 mm60 mmsame
Width60 mm60 mmsame
Web thickness0 mm0 mmsame
Flange thickness0 mm0 mmsame
Area10.7 cm²10.4 cm²+2.9%
Second moment, major (Iy)53.3 cm⁴50.5 cm⁴+5.5%
Plastic modulus, major (Wpl,y)21.9 cm³20.9 cm³+4.8%
Elastic modulus, major (Wel,y)17.8 cm³16.8 cm³+6.0%
Second moment, minor (Iz)53.3 cm⁴50.5 cm⁴+5.5%
Plastic modulus, minor (Wpl,z)21.9 cm³20.9 cm³+4.8%
Radius of gyration, minor (iz)2.23 cm2.21 cm+0.9%
Torsion constant (It)86.4 cm⁴86.4 cm⁴same

SHS 60×60×5 to BS EN 10210-2:2006; CF SHS 60×60×5 to BS EN 10219-2:2006. Difference is expressed relative to CF SHS 60×60×5.

How to choose between them

On stiffness, SHS 60×60×5 has the larger second moment of area: 53.3 cm⁴ against 50.5 cm⁴, a difference of 5.5%. This matters more often than the strength comparison, because on normal floor spans deflection rather than bending capacity sets the beam size - so if the two are close on modulus but apart on inertia, the stiffer one is usually the better answer even when it is not the stronger one.

Measured as bending capacity per kilogram, the two are equally efficient (2.6 against 2.6 cm³ per kg/m), so on a pure steel-tonnage basis there is nothing to choose between them. The decision comes down to availability, connection detailing and what the rest of the frame uses.

In short, SHS 60×60×5 is the stronger section and CF SHS 60×60×5 is the lighter one; where those are the same section, it is the clear choice, and where they are not, decide on whether your design is governed by capacity or by tonnage.

Common questions

SHS 60×60×5 is the stronger of the two in bending, with a plastic modulus of 21.9 cm³ against 20.9 cm³ - 4.8% more. At the same steel grade that translates directly into moment capacity, since M_pl,Rd = W_pl x f_y / gamma_M0.

CF SHS 60×60×5 at 8.13 kg/m, against 8.42 kg/m for the other - a saving of 3.6%. Over a repeated floor beam that is a real cost difference, but check it against the deflection case before taking it.

Structurally it is the closest equivalent we hold: CF SHS 60×60×5 gives 20.9 cm³ of plastic modulus and 50.5 cm⁴ of inertia against 21.9 cm³ and 53.3 cm⁴. Re-check deflection and the connection details before swapping, since the flange and web thicknesses differ.

SHS 60×60×5, with a second moment of area of 53.3 cm⁴ against 50.5 cm⁴ (5.5% more). Deflection under a uniform load goes as 5wL⁴/384EI, so it is inversely proportional to I - on a span where the deflection limit governs rather than strength, this is the number that decides the section.

Related comparisons

SHS 60×60×5 vs SHS 63.5×63.5×4.5
Rate this
No ratings yet
Sign in to join the discussion.
Loading…