CF SHS 60×60×5 - Section Properties

The CF SHS 60×60×5 is a square hollow section with a mass of 8.13 kg/m, an overall depth of 60 mm and width of 60 mm and a wall thickness of 5 mm. It has a cross-sectional area of 10.4 cm², a second moment of area Iᵧ of 50.5 cm⁴, a plastic modulus Wₚₗ,ᵧ of 20.9 cm³, tabulated by CivilAxis from BS EN 10219-2:2006 (SCI P363 Blue Book).

Mass
8.13 kg/m
Depth
60 mm
Width
60 mm
Wall thickness
5 mm
Area
10.4 cm²
Ask about capacity, buckling or detailing for CF SHS 60×60×5.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
SHS Cold-formed section profile showing the dimension symbols used for CF SHS 60×60×5

Dimension symbols for SHS Cold-formed sections. Not to scale.

CF SHS 60×60×5 section properties to BS EN 10219-2:2006.

Geometry

Depth of sectionh60
Width of sectionb60
Wall thicknesst5

Mass and area

Mass per metremass8.13
Cross-sectional areaA10.4

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy50.5
Elastic section modulus about y-axisWel,y16.8
Plastic section modulus about y-axisWpl,y20.9
Radius of gyration about y-axisiy2.21

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz50.5
Elastic section modulus about z-axisWel,z16.8
Plastic section modulus about z-axisWpl,z20.9
Radius of gyration about z-axisiz2.21

Torsion and warping

Torsion constant (St Venant)It86.4
Section modulus for torsionWt25.6

Surface area

Surface area per metreSA/m0.223
Surface area per tonneSA/t27.4m²/t

Is CF SHS 60×60×5 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 62% utilised, deflection governs
Bending35%
2.6 / 7.4 kNm
Shear10%
10.5 / 106.6 kN
Deflection62%
1.7 / 2.8 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about CF SHS 60×60×5

CF SHS 60×60×5 has a mass of 8.13 kg/m, tabulated to BS EN 10219-2:2006. A 12 m length therefore weighs about 98 kg, which is the figure to use for a steel take-off or when checking a lift.

CF SHS 60×60×5 has a depth of 60 mm, a width of 60 mm, a wall thickness of 5 mm, with a cross-sectional area of 10.4 cm². These are the nominal dimensions from BS EN 10219-2:2006; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 20.9 cm³, and the elastic modulus Wel,y is 16.8 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 7 kNm before any stability check.

The second moment of area about the major axis, Iy, is 50.5 cm⁴, and about the minor axis Iz is 50.5 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

iy is 2.21 cm about the major axis and iz is 2.21 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 2.21 cm a 0.2 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 86.4 cm⁴. Closed sections carry torsion in a shear flow around the perimeter, which makes them far stiffer in torsion than an open section of the same weight and is usually why one is specified.

Related SHS Cold-formed sizes

CF SHS 50×50×4CF SHS 50×50×5CF SHS 60×60×3CF SHS 60×60×4CF SHS 60×60×6CF SHS 70×70×3CF SHS 70×70×3.5CF SHS 70×70×4

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs SHS 60×60×5

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 SHS vs RHS vs CHS: choosing a hollow steel section
All SHS Cold-formed sizes
Square Hollow Sections - Cold-formed (BS EN 10219)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…