CivilAxisCivilAxis
☕ Support🌐 Community

UB 533×165×75 vs W 21X50

UB 533×165×75 is an UB section from the UK Blue Book (SCI P363); W 21X50 is the closest equivalent in the American AISC Shapes Database. They are close to interchangeable in bending: 1810 cm³ against 1802.6 cm³ of plastic modulus, a difference of 0.4%. They weigh essentially the same, 74.7 kg/m and 74.4 kg/m. Both are about 529 mm deep, so either fits the same construction zone.

Section properties side by side. Bold marks the more favourable value where one is.
PropertyUB 533×165×75
UB
W 21X50
W
Difference
Mass74.7 kg/m74.4 kg/m+0.4%
Depth529.1 mm528.3 mm+0.2%
Width165.9 mm165.9 mmsame
Web thickness9.7 mm9.7 mmsame
Flange thickness13.6 mm13.6 mmsame
Area95.2 cm²94.8 cm²+0.4%
Second moment, major (Iy)41,100 cm⁴40,957 cm⁴+0.3%
Plastic modulus, major (Wpl,y)1,810 cm³1,802.6 cm³+0.4%
Elastic modulus, major (Wel,y)1,550 cm³1,548.6 cm³+0.1%
Second moment, minor (Iz)1,040 cm⁴1,036 cm⁴+0.4%
Plastic modulus, minor (Wpl,z)200 cm³199.92 cm³same
Radius of gyration, minor (iz)3.3 cm3.3 cmsame
Torsion constant (It)47.9 cm⁴47.45 cm⁴+0.9%

UB 533×165×75 to BS EN 10365:2017; W 21X50 to AISC Shapes Database v16.0. Difference is expressed relative to W 21X50.

How to choose between them

On stiffness, UB 533×165×75 has the larger second moment of area: 41,100 cm⁴ against 40,957 cm⁴, a difference of 0.3%. This matters more often than the strength comparison, because on normal floor spans deflection rather than bending capacity sets the beam size - so if the two are close on modulus but apart on inertia, the stiffer one is usually the better answer even when it is not the stronger one.

Measured as bending capacity per kilogram, the two are equally efficient (24.2 against 24.2 cm³ per kg/m), so on a pure steel-tonnage basis there is nothing to choose between them. The decision comes down to availability, connection detailing and what the rest of the frame uses.

These come from different catalogues, so treat the swap as a design change rather than a like-for-like substitution. UB sections are specified to BS EN 10365:2017 and W to AISC Shapes Database v16.0; the steel grades, tolerances and available lengths differ, connection details and bolt gauges are set out differently, and the two are rarely both stocked in the same market. Check availability before changing a section on a drawing to save a marginal amount of weight.

In short, these two are genuine equivalents. Pick whichever your supplier stocks and the rest of the frame already uses.

Common questions

They are effectively equal in bending. UB 533×165×75 has a plastic modulus of 1810 cm³ and W 21X50 has 1802.6 cm³, a difference of only 0.4% - within the margin that section choice normally turns on. Compare stiffness and availability instead.

Neither meaningfully: UB 533×165×75 is 74.7 kg/m and W 21X50 is 74.4 kg/m. On a tonnage basis they cost the same.

Structurally it is the closest equivalent we hold: W 21X50 gives 1802.6 cm³ of plastic modulus and 40,957 cm⁴ of inertia against 1810 cm³ and 41,100 cm⁴. But they are from different catalogues (BS EN 10365:2017 and AISC Shapes Database v16.0), so this is a design change, not a drop-in swap: re-check deflection, connection detailing and local availability.

UB 533×165×75, with a second moment of area of 41,100 cm⁴ against 40,957 cm⁴ (0.3% more). Deflection under a uniform load goes as 5wL⁴/384EI, so it is inversely proportional to I - on a span where the deflection limit governs rather than strength, this is the number that decides the section.

Related comparisons

W 21X48 vs UB 533×165×75
Rate this
No ratings yet
Sign in to join the discussion.