UB 610×229×140 is an UB section from the UK Blue Book (SCI P363); W 24X94 is the closest equivalent in the American AISC Shapes Database. They are close to interchangeable in bending: 4140 cm³ against 4162.3 cm³ of plastic modulus, a difference of 0.5%. They weigh essentially the same, 139.9 kg/m and 139.9 kg/m. Both are about 617 mm deep, so either fits the same construction zone.

Section properties side by side. Bold marks the more favourable value where one is.
PropertyUB 610×229×140
UB
W 24X94
W
Difference
Mass139.9 kg/m139.9 kg/msame
Depth617.2 mm617.2 mmsame
Width230.2 mm230.4 mm-0.1%
Web thickness13.1 mm13.1 mmsame
Flange thickness22.1 mm22.2 mm-0.5%
Area178 cm²178.7 cm²-0.4%
Second moment, major (Iy)112,000 cm⁴112,382 cm⁴-0.3%
Plastic modulus, major (Wpl,y)4,140 cm³4,162.3 cm³-0.5%
Elastic modulus, major (Wel,y)3,620 cm³3,637.9 cm³-0.5%
Second moment, minor (Iz)4,510 cm⁴4,537 cm⁴-0.6%
Plastic modulus, minor (Wpl,z)611 cm³614.51 cm³-0.6%
Radius of gyration, minor (iz)5.03 cm5.03 cmsame
Torsion constant (It)216 cm⁴218.9 cm⁴-1.3%

UB 610×229×140 to BS EN 10365:2017; W 24X94 to AISC Shapes Database v16.0. Difference is expressed relative to W 24X94.

How to choose between them

On stiffness, W 24X94 has the larger second moment of area: 112,382 cm⁴ against 112,000 cm⁴, a difference of 0.3%. This matters more often than the strength comparison, because on normal floor spans deflection rather than bending capacity sets the beam size - so if the two are close on modulus but apart on inertia, the stiffer one is usually the better answer even when it is not the stronger one.

Measured as bending capacity per kilogram, the two are equally efficient (29.6 against 29.8 cm³ per kg/m), so on a pure steel-tonnage basis there is nothing to choose between them. The decision comes down to availability, connection detailing and what the rest of the frame uses.

These come from different catalogues, so treat the swap as a design change rather than a like-for-like substitution. UB sections are specified to BS EN 10365:2017 and W to AISC Shapes Database v16.0; the steel grades, tolerances and available lengths differ, connection details and bolt gauges are set out differently, and the two are rarely both stocked in the same market. Check availability before changing a section on a drawing to save a marginal amount of weight.

In short, these two are genuine equivalents. Pick whichever your supplier stocks and the rest of the frame already uses.

Common questions

They are effectively equal in bending. UB 610×229×140 has a plastic modulus of 4140 cm³ and W 24X94 has 4162.3 cm³, a difference of only 0.5% - within the margin that section choice normally turns on. Compare stiffness and availability instead.

Neither meaningfully: UB 610×229×140 is 139.9 kg/m and W 24X94 is 139.9 kg/m. On a tonnage basis they cost the same.

Structurally it is the closest equivalent we hold: W 24X94 gives 4162.3 cm³ of plastic modulus and 112,382 cm⁴ of inertia against 4140 cm³ and 112,000 cm⁴. But they are from different catalogues (BS EN 10365:2017 and AISC Shapes Database v16.0), so this is a design change, not a drop-in swap: re-check deflection, connection detailing and local availability.

W 24X94, with a second moment of area of 112,382 cm⁴ against 112,000 cm⁴ (0.3% more). Deflection under a uniform load goes as 5wL⁴/384EI, so it is inversely proportional to I - on a span where the deflection limit governs rather than strength, this is the number that decides the section.