UB 610×229×140 vs W 24X94
UB 610×229×140 is an UB section from the UK Blue Book (SCI P363); W 24X94 is the closest equivalent in the American AISC Shapes Database. They are close to interchangeable in bending: 4140 cm³ against 4162.3 cm³ of plastic modulus, a difference of 0.5%. They weigh essentially the same, 139.9 kg/m and 139.9 kg/m. Both are about 617 mm deep, so either fits the same construction zone.
| Property | UB 610×229×140 UB | W 24X94 W | Difference |
|---|---|---|---|
| Mass | 139.9 kg/m | 139.9 kg/m | same |
| Depth | 617.2 mm | 617.2 mm | same |
| Width | 230.2 mm | 230.4 mm | -0.1% |
| Web thickness | 13.1 mm | 13.1 mm | same |
| Flange thickness | 22.1 mm | 22.2 mm | -0.5% |
| Area | 178 cm² | 178.7 cm² | -0.4% |
| Second moment, major (Iy) | 112,000 cm⁴ | 112,382 cm⁴ | -0.3% |
| Plastic modulus, major (Wpl,y) | 4,140 cm³ | 4,162.3 cm³ | -0.5% |
| Elastic modulus, major (Wel,y) | 3,620 cm³ | 3,637.9 cm³ | -0.5% |
| Second moment, minor (Iz) | 4,510 cm⁴ | 4,537 cm⁴ | -0.6% |
| Plastic modulus, minor (Wpl,z) | 611 cm³ | 614.51 cm³ | -0.6% |
| Radius of gyration, minor (iz) | 5.03 cm | 5.03 cm | same |
| Torsion constant (It) | 216 cm⁴ | 218.9 cm⁴ | -1.3% |
UB 610×229×140 to BS EN 10365:2017; W 24X94 to AISC Shapes Database v16.0. Difference is expressed relative to W 24X94.
How to choose between them
On stiffness, W 24X94 has the larger second moment of area: 112,382 cm⁴ against 112,000 cm⁴, a difference of 0.3%. This matters more often than the strength comparison, because on normal floor spans deflection rather than bending capacity sets the beam size - so if the two are close on modulus but apart on inertia, the stiffer one is usually the better answer even when it is not the stronger one.
Measured as bending capacity per kilogram, the two are equally efficient (29.6 against 29.8 cm³ per kg/m), so on a pure steel-tonnage basis there is nothing to choose between them. The decision comes down to availability, connection detailing and what the rest of the frame uses.
These come from different catalogues, so treat the swap as a design change rather than a like-for-like substitution. UB sections are specified to BS EN 10365:2017 and W to AISC Shapes Database v16.0; the steel grades, tolerances and available lengths differ, connection details and bolt gauges are set out differently, and the two are rarely both stocked in the same market. Check availability before changing a section on a drawing to save a marginal amount of weight.
In short, these two are genuine equivalents. Pick whichever your supplier stocks and the rest of the frame already uses.