HSS 20X12X1 - Section Properties

The HSS 20X12X1 is a steel section with a mass of 290.8 kg/m, an overall depth of 508 mm and width of 304.8 mm and a wall thickness of 23.6 mm. It has a cross-sectional area of 347.1 cm², a second moment of area Iᵧ of 114047 cm⁴, a plastic modulus Wₚₗ,ᵧ of 5637.2 cm³, tabulated by CivilAxis from AISC Shapes Database v16.0.

Mass
195.4 lb/ft (290.8 kg/m)
Depth
20 in (508 mm)
Width
12 in (304.8 mm)
Wall thickness
0.93 in (23.6 mm)
Area
53.8 in² (347.1 cm²)
Ask about capacity, buckling or detailing for HSS 20X12X1.
🔍 Open the full Steel Catalogue
or pick a unit on any row
HSS section profile showing the dimension symbols used for HSS 20X12X1

Dimension symbols for HSS sections. Not to scale.

HSS 20X12X1 section properties to AISC Shapes Database v16.0.

Geometry

Depth of sectionh20
508 mm
Width of sectionb12
304.8 mm
Web thicknesstw0.93
23.6 mm
Wall thicknesst0.93
23.6 mm

Mass and area

Mass per metremass195.4
290.8 kg/m
Cross-sectional areaA53.8
347.1 cm²

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy2740
114047 cm⁴
Elastic section modulus about y-axisWel,y274
4490.1 cm³
Plastic section modulus about y-axisWpl,y344
5637.2 cm³
Radius of gyration about y-axisiy7.14
18.14 cm

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz1230
51196 cm⁴
Elastic section modulus about z-axisWel,z205
3359.3 cm³
Plastic section modulus about z-axisWpl,z241
3949.3 cm³
Radius of gyration about z-axisiz4.78
12.14 cm

Torsion and warping

Torsion constant (St Venant)It2820
117377 cm⁴

Is HSS 20X12X1 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 61% utilised, deflection governs
Bending30%
581.3 / 1944.8 kNm
Shear5%
232.5 / 4321.1 kN
Deflection61%
16.9 / 27.8 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about HSS 20X12X1

HSS 20X12X1 has a mass of 195.4 lb/ft (290.8 kg/m), tabulated to AISC Shapes Database v16.0. A 12 m length therefore weighs about 3490 kg, which is the figure to use for a steel take-off or when checking a lift.

HSS 20X12X1 has a depth of 20 in (508 mm), a width of 12 in (304.8 mm), a web thickness of 0.93 in (23.6 mm), a wall thickness of 0.93 in (23.6 mm), with a cross-sectional area of 53.8 in² (347.1 cm²). These are the nominal dimensions from AISC Shapes Database v16.0; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 5,637.2 cm³, and the elastic modulus Wel,y is 4,490.1 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 2001 kNm before any stability check.

The second moment of area about the major axis, Iy, is 114,047 cm⁴, and about the minor axis Iz is 51,196 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

iy is 18.14 cm about the major axis and iz is 12.14 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 12.14 cm a 1.2 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 117,377 cm⁴. Closed sections carry torsion in a shear flow around the perimeter, which makes them far stiffer in torsion than an open section of the same weight and is usually why one is specified.

Related HSS sizes

HSS 20X16X1-2HSS 20X16X3-8HSS 20X16X5-16HSS 20X16X1-4HSS 20X12X7-8HSS 20X12X3-4HSS 20X12X5-8HSS 20X12X1-2

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 SHS vs RHS vs CHS: choosing a hollow steel section
All HSS sizes
AISC HSS (Hollow Structural Sections)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…